Stress distributions in the acetabular region--I. Before and after total joint replacement.

作者信息

Vasu R, Carter D R, Harris W H

出版信息

J Biomech. 1982;15(3):155-64. doi: 10.1016/0021-9290(82)90247-0.

Abstract

Two-dimensional finite element analyses of the acetabular region before and after hip replacement were conducted. The distribution of pressure at the acetabular surface for the single limb stance phase of gait was transformed to nodal loads to stimulate in vivo loading conditions. A nonhomogeneous distribution of bone elastic properties was incorporated in the models. The results demonstrated that the principal stresses in the normal acetabulum were aligned with the principal orientations of the trabeculae. Total joint replacement increased the von Mises' equivalent stresses in the cancellous bone immediately superior to the acetabular cup, and increased stresses in the medial wall of the ilium. Biaxial, tension-compression stresses were created in the layer of bone cement and introduced in the medial wall of the ilium. Tensile stresses in the bone cement were greatest at the superior roof and at the inferior margin of the cup. Tensile stresses in the cup were more pronounced at the margins, particularly near the inferior lip. The cup tended to close in such a manner as to grip the head of the femoral component as it was pressed between the medial and lateral walls of the ilium.

摘要

对髋关节置换前后髋臼区域进行了二维有限元分析。将步态单肢站立阶段髋臼表面的压力分布转换为节点载荷,以模拟体内加载条件。模型中纳入了骨弹性特性的非均匀分布。结果表明,正常髋臼中的主应力与小梁的主方向一致。全关节置换增加了髋臼杯上方紧邻的松质骨中的冯·米塞斯等效应力,并增加了髂骨内侧壁的应力。在骨水泥层中产生了双轴拉压应力,并传递到髂骨内侧壁。骨水泥中的拉应力在髋臼杯的上缘和下缘最大。髋臼杯边缘的拉应力更明显,尤其是在下唇附近。髋臼杯倾向于以一种方式闭合,以便在股骨部件的头部被压在髂骨内侧壁和外侧壁之间时抓住它。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验