• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Measurement of glucose concentration in the presence of coreactants with a platinum electrode.

作者信息

Lerner H, Soeldner J S, Colton C K, Giner J

出版信息

Diabetes Care. 1982 May-Jun;5(3):229-37. doi: 10.2337/diacare.5.3.229.

DOI:10.2337/diacare.5.3.229
PMID:7172990
Abstract

An implantable glucose sensor is being developed that is based on the use of a high-area platinum electrode. The sensor is operated in a controlled potential mode, in which the potential of the platinum working electrode versus an unpolarized reference electrode is periodically varied according to a preselected voltage-time regimen. The change in potential is accompanied by a flow of current between the platinum working electrode and a counter-electrode. This current serves to periodically rejuvenate the electrode surface and to provide a signal that is proportional to the glucose concentration. A method for analyzing this signal has been developed, the compensated net charge (CNC) method, that involves integration of the current over one complete potential cycle. This method significantly improves both the sensitivity and selectivity for determining glucose in the presence of the normal physiologic coreactants. For a solution containing glucose, amino acids, and urea, a change in glucose concentration from 50 to 150 mg/dl gives about a 50% change in the net charge. A change in the urea concentration from 20 to 40 mg/dl has no effect on the net charge. A change in the amino acids concentration from 35 to 65 mg/dl has little effect on the net charge above a glucose concentration of about 100 mg/dl. Negligible effects on the net charge have also been found for creatinine (0-1.5 mg/dl) and uric acid (0-4 mg/dl).

摘要

相似文献

1
Measurement of glucose concentration in the presence of coreactants with a platinum electrode.
Diabetes Care. 1982 May-Jun;5(3):229-37. doi: 10.2337/diacare.5.3.229.
2
Amperometric glucose sensor: short-term, in vivo test.安培型葡萄糖传感器:短期体内测试。
Diabetes Care. 1982 May-Jun;5(3):238-44. doi: 10.2337/diacare.5.3.238.
3
Electrocatalytic glucose sensor.电催化葡萄糖传感器。
Horm Metab Res Suppl. 1988;20:43-7.
4
In vitro and in vivo testing of an electrocatalytic glucose sensor.一种电催化葡萄糖传感器的体外和体内测试
ASAIO Trans. 1990 Jul-Sep;36(3):M591-4.
5
Glucose determination by differential pulse voltammetry with a platinum electrode.用铂电极通过差分脉冲伏安法测定葡萄糖。
Biomed Biochim Acta. 1989;48(11-12):883-9.
6
Immobilized enzyme electrodes for the potentiometric measurement of glucose concentration: immobilization techniques and materials.用于葡萄糖浓度电位测量的固定化酶电极:固定化技术与材料
J Biomed Mater Res. 1979 Nov;13(6):921-35. doi: 10.1002/jbm.820130610.
7
A potentially implantable enzyme electrode for amperometric measurement of glucose.一种用于葡萄糖安培测量的潜在可植入酶电极。
Horm Metab Res Suppl. 1988;20:8-13.
8
Interference of glucose sensing by amino acids.
ASAIO J. 1994 Jan-Mar;40(1):33-40.
9
Potentiometric measurement of glucose concentration with an immobilized glucose oxidase/catalase electrode.用固定化葡萄糖氧化酶/过氧化氢酶电极电位法测定葡萄糖浓度。
Diabetes Care. 1982 May-Jun;5(3):199-202. doi: 10.2337/diacare.5.3.199.
10
Urea biosensor based on PANi(urease)-Nafion/Au composite electrode.基于聚苯胺(脲酶)- 全氟磺酸/金复合电极的尿素生物传感器。
Biosens Bioelectron. 2004 Jul 30;20(1):15-23. doi: 10.1016/j.bios.2003.11.028.