An evaluation of blood smears made by a new method using a spinner and diluted blood.

作者信息

Nourbakhsh M, Atwood J G, Raccio J, Seligson D

出版信息

Am J Clin Pathol. 1978 Dec;70(6):885-92. doi: 10.1093/ajcp/70.6.885.

DOI:10.1093/ajcp/70.6.885
PMID:727173
Abstract

Blood smears were prepared with the use of a spinner, which rotated with a fixed velocity for a fixed time. All blood samples used for spun smears were diluted with a fixed ratio of buffered isotonic saline solution. Distribution of cells in these smears was found to be random. The average number of cells per unit area was substantially uniform from place to place on the same slide and on multiple slides made with the smae sample. The distribution of leukocytes by type was also iniform. For different blood samples, the average number of cells per unit area in the smears correlated well with the measured cell concentrations per unit volume in the samples for leukocytes, erythrocytes and platelets. Leukocyte differential counts on replicate spun smears using the same bloods also agreed to within the sampling error. They similarly agreed with differential counts on pulled smears made from undiluted samples of the same bloods. With few exceptions, erythrocytic morphology on the spun smears was comparable to that on the good areas of pulled smears made with undiluted samples of the same bloods. Nearly all the spun smears were suitable for both viual and fully automated hematologic examination for leukocytes, erythrocytes, and platelets. This was true over nearly the whole area of each spun slide. In these ways this spinner method makes smears whose consistently high quality is little affected by either the properties of the blood sample or the skill of maker.

摘要

相似文献

1
An evaluation of blood smears made by a new method using a spinner and diluted blood.
Am J Clin Pathol. 1978 Dec;70(6):885-92. doi: 10.1093/ajcp/70.6.885.
2
Examination of peripheral blood films using automated microscopy; evaluation of Diffmaster Octavia and Cellavision DM96.使用自动显微镜检查外周血涂片;评估Diffmaster Octavia和Cellavision DM96。
J Clin Pathol. 2007 Jan;60(1):72-9. doi: 10.1136/jcp.2005.035402. Epub 2006 May 12.
3
Segmentation of leukocytes and erythrocytes in blood smear images.血液涂片图像中白细胞和红细胞的分割
Annu Int Conf IEEE Eng Med Biol Soc. 2008;2008:3075-8. doi: 10.1109/IEMBS.2008.4649853.
4
Comparison of five methods for preparing blood smears.
Am J Med Technol. 1976 Mar;42(3):71-8.
5
[Comparative studies of blood smears prepared by the wedge method and spinner method].[楔形法和旋转法制备血涂片的比较研究]
Rinsho Byori. 1985 Nov;33(11):1319-23.
6
Sample preparation variation and its effects on automated blood cell differential analysis.样本制备差异及其对自动化血细胞分类分析的影响。
Anal Quant Cytol. 1979 Nov-Dec;1(3):187-201.
7
Estimating leukocyte, platelet, and erythrocyte counts in rats by blood smear examination.
Vet Clin Pathol. 2009 Jun;38(2):157-62. doi: 10.1111/j.1939-165X.2009.00110.x. Epub 2009 Mar 12.
8
Improved mouse blood smears using the DiffSpin slide spinner.使用DiffSpin载玻片旋转器改进小鼠血涂片。
Vet Clin Pathol. 2001;30(4):197-200.
9
Improved flow cytometric method to enumerate residual cells: minimal linear detection limits for platelets, erythrocytes, and leukocytes.用于计数残留细胞的改进流式细胞术方法:血小板、红细胞和白细胞的最小线性检测限
Cytometry. 2002 Aug 15;50(4):231-7. doi: 10.1002/cyto.10125.
10
Improved automated differential counts of leukocytes from newborn infants using pre-dilution of blood samples.使用血液样本预稀释改进新生儿白细胞自动分类计数。
Eur J Haematol Suppl. 1990;53:54-6. doi: 10.1111/j.1600-0609.1990.tb01529.x.

引用本文的文献

1
Performance of automated slidemakers and stainers in a working laboratory environment - routine operation and quality control.自动化玻片制备和染色机在工作实验室环境中的性能 - 常规操作和质量控制。
Int J Lab Hematol. 2010 Feb;32(1 Pt 1):e64-76. doi: 10.1111/j.1751-553X.2009.01141.x. Epub 2009 Feb 11.