Suppr超能文献

通过延长装置吸入的加压悬浮气雾剂的沉积。

Deposition of pressurized suspension aerosols inhaled through extension devices.

作者信息

Newman S P, Morén F, Pavia D, Little F, Clarke S W

出版信息

Am Rev Respir Dis. 1981 Sep;124(3):317-20. doi: 10.1164/arrd.1981.124.3.317.

Abstract

Only a small fraction of the dose from a pressurized aerosol inhaler reaches the lung, because most is deposited on the upper airways by inertial impaction. We have investigated the effects on aerosol deposition of two spacer devices (a 10-cm tube and a 22-cm cone) by incorporating teflon particles (mass median aerodynamic diameter, 3.2 micrometer) labeled with 99mTc into pressurized canisters. Ten subjects with obstructive airway disease inhaled the aerosol in a controlled manner from a conventional actuator alone or in combination with the tube or the cone. Radioaerosol distribution was measured using a shadowshield whole body counter. Deposition on the conducting airways was significantly improved by both spacers, but alveolar deposition was unchanged. Initial oropharyngeal deposition was reduced by both spacers in all 10 patients. We conclude that the spacer devices may have a role to play in aerosol therapy by increasing drug availability to the lung, while at the same time decreasing unwanted drug deposition in the oropharynx.

摘要

由于大部分剂量通过惯性碰撞沉积在上呼吸道,因此来自压力定量气雾剂吸入器的剂量只有一小部分能到达肺部。我们通过将标记有99mTc的聚四氟乙烯颗粒(质量中值空气动力学直径为3.2微米)加入压力罐中,研究了两种储雾罐装置(一根10厘米长的管子和一个22厘米长的圆锥体)对气雾剂沉积的影响。10名患有阻塞性气道疾病的受试者以可控方式从传统吸入器单独吸入气雾剂,或与管子或圆锥体组合吸入。使用带有屏蔽的全身计数器测量放射性气雾剂的分布。两种储雾罐均显著改善了在传导气道的沉积,但肺泡沉积未改变。在所有10名患者中,两种储雾罐均减少了初始口咽沉积。我们得出结论,储雾罐装置可能在气雾剂治疗中发挥作用,通过增加药物到达肺部的可用性,同时减少药物在口咽部的不必要沉积。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验