图书馆中的真菌:一项空气测量调查。

Fungi in libraries: an aerometric survey.

作者信息

Burge H P, Boise J R, Solomon W R, Bandera E

出版信息

Mycopathologia. 1978 Oct 16;64(2):67-72. doi: 10.1007/BF00440963.

Abstract

The possible role of fungi as allergic contaminants in book collections has been investigated in eleven University of Michigan Libraries. Air in the stacks of each of the eleven libraries was sampled on three occasions (2 or 4--10 minute samples on each occasion) with Andersen Volumetric viable particle samplers. Books were handled during sampling in half the samples each day. In addition on each sampling day a location in the same building away from book storage and an outdoor location were sampled. Library spore levels were generally low. Outdoor levels consistently exceeded indoor levels. Air conditioned (AC) libraries had lower spore levels and indoor/outdoor ratios than conventionally ventilated (CV) libraries. Handling books during sampling increased spore counts in all libraries, but strikingly in CV libraries. Fungus taxa recovered were similar to those encountered in domestic interiors and outside locations in our area. The overall low spore levels and lack of a distinctive library mycoflora suggest that other sources should be sought for library-based respiratory symptoms.

摘要

密歇根大学的十一个图书馆对真菌作为藏书过敏污染物的潜在作用进行了调查。使用安德森体积活粒子采样器,在十一个图书馆的书库中,分三次(每次采集2个或4 - 10分钟的样本)对空气进行采样。每天有一半的样本在采样期间翻动书籍。此外,在每个采样日,对同一建筑内远离藏书区的一个地点以及室外的一个地点进行采样。图书馆的孢子水平普遍较低。室外水平始终超过室内水平。与传统通风(CV)的图书馆相比,装有空调(AC)的图书馆孢子水平和室内/室外比率更低。在采样期间翻动书籍会增加所有图书馆中的孢子计数,但在CV图书馆中尤为显著。回收的真菌分类群与我们地区家庭室内和室外环境中遇到的类似。孢子水平总体较低以及缺乏独特的图书馆真菌群落表明,对于基于图书馆的呼吸道症状,应寻找其他来源。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验