Bradsher R W, Pappas P G
Department of Medicine, University of Arkansas for Medical Sciences, Little Rock 72205, USA.
South Med J. 1995 Dec;88(12):1256-9. doi: 10.1097/00007611-199512000-00013.
Serologic tests for the diagnosis of blastomycosis have had inadequate sensitivity, but results are improved with enzyme immunoassay (EIA) with A-antigen of Blastomyces dermatitidis. The Premier Blastomyces EIA kit (Meridian Diagnostics Inc, Cincinnati, Ohio) detected antibody against the B dermatitidis A-antigen in sera from 104 of 125 patients (83%) with culture-proven blastomycosis. Semiquantitative index values (positivity multiplied by the dilution) ranged from 1.0 to 423.3; the degree of positivity correlated with disease activity. Immunodiffusion bands were infrequently detected, with positive specimens from only 19 (21%) of 92 patients with blastomycosis. In 8 of 24 patients with histoplasmosis, 24 of 51 specimens (47%) were positive for Blastomyces antibody by EIA; index values were lower, with a mean of 3.8 versus 24.3 for sera from patients with blastomycosis. Only 1 of 13 patients with other fungal infections had positive results with EIA. This EIA system provided better sensitivity than previously available commercial systems for serodiagnosis of blastomycosis.
用于诊断芽生菌病的血清学检测灵敏度不足,但使用皮炎芽生菌A抗原的酶免疫测定(EIA)可提高检测结果。Premier芽生菌EIA试剂盒(Meridian诊断公司,俄亥俄州辛辛那提)在125例经培养证实为芽生菌病的患者中,检测出104例(83%)患者血清中存在抗皮炎芽生菌A抗原的抗体。半定量指数值(阳性率乘以稀释倍数)范围为1.0至423.3;阳性程度与疾病活动度相关。免疫扩散条带很少检测到,92例芽生菌病患者中只有19例(21%)的标本呈阳性。在24例组织胞浆菌病患者中,有8例(51份标本中的24份,47%)通过EIA检测出芽生菌抗体呈阳性;指数值较低,芽生菌病患者血清的平均指数值为24.3,而组织胞浆菌病患者血清的平均指数值为3.8。13例其他真菌感染患者中只有1例EIA检测结果为阳性。该EIA系统在芽生菌病血清诊断方面比以前的商业系统具有更高的灵敏度。