Suppr超能文献

[A-201和AS-104细胞分离器的单针分离结果]

[Single needle results with A-201 and AS-104 cell separators].

作者信息

Moog R

机构信息

Institut für Transfusionsmedizin, Universitätsklinikum Essen, BRD.

出版信息

Beitr Infusionsther. 1993;31:104-6.

PMID:7693236
Abstract

In plateletpheresis, new single-needle techniques have been developed for the cell separators A 201 (Baxter) and AS 104 (Fresenius). These new techniques were studied concerning donation time, ACD consumption, platelet yield, separation efficiency, erythrocyte and leukocyte contamination. The total amount of thrombocytes and the separation efficiency were significantly better with the single-needle version of the AS 104 apparatus than with the A 201 device. The contamination values were significantly lower with the AS 104 machine.

摘要

在血小板单采术中,已为A 201(百特公司)和AS 104(费森尤斯公司)血细胞分离机开发了新的单针技术。对这些新技术在献血时间、ACD消耗量、血小板产量、分离效率、红细胞和白细胞污染方面进行了研究。与A 201设备相比,AS 104设备的单针版本采集的血小板总量和分离效率明显更高。AS 104机器的污染值显著更低。