A test of renal viability using the uptake of 125I-iodohippurate by kidney biopsy specimens has been developed. It is applicable to all kidneys irrespective of the method of storage. The uptake of 125I-iodohippurate in experimental kidneys correlated well with warm or cold ischaemia time and subsequent renal function. The test was used for human cadaver kidneys offered for transplantation and there was good correlation between iodohippurate uptake and warm ischaemic time. With this test, prediction of renal function was accurate in 85% of human cadaver kidneys transplanted. Pulsatile perfusion had no effect on cadaver kidneys as measured by this test.

摘要

一种利用肾活检标本摄取125I-碘马尿酸来检测肾活力的方法已被开发出来。它适用于所有肾脏,无论其保存方法如何。实验性肾脏中125I-碘马尿酸的摄取与热缺血或冷缺血时间以及随后的肾功能密切相关。该检测方法用于供移植的人类尸体肾脏,碘马尿酸摄取与热缺血时间之间存在良好的相关性。通过该检测,85%接受移植的人类尸体肾脏的肾功能预测是准确的。用该检测方法测量,搏动灌注对尸体肾脏没有影响。