Le Gargasson J F, Rigaudiere F, Guez J E, Gaudric A, Grall Y
Biophysique (Département Vision), Université Paris VII, U.F.R. Lariboisière-St-Louis, France.
Doc Ophthalmol. 1994;86(3):227-38. doi: 10.1007/BF01203546.
A study was designed to validate a functional investigation performed with the scanning laser ophthalmoscope before surgery for macular holes in 12 eyes: The assessment included fundus examination, a functional examination resulting in evaluation of the preferred retinal lows, visual acuity and recording of visual evoked potentials. The preferred retinal locus was evaluated by presenting a small square area, and visual acuity was determined by means of calibrated figures. The visual evoked potentials were evoked by three alternating checkerboards (check size, 30', 2 Hz) centered over the hole and seen at an angle of 6.5 x 6.5 degrees, 2.5 x 2.5 degrees and 6.5 x 6.5 degrees with central exclusion of 2.5 x 2.5 degrees. The appearance of the fundus visualized by scanning laser ophthalmoscopy consisted of a clear central disk corresponding to the hole, surrounded by a very dark ring, associated with a second, less dark ring with unclear margins. Fixation was unstable in one case with a visual acuity of 20/70. In 11 cases, fixation was localized to the superior retina with a visual acuity superior to 20/70. The visual evoked potentials evoked by 6.5 x 6.5 degrees were discernible in all 12 eyes; visual evoked potential by annular stimuli were discernible in 11 cases. The 2.5 x 2.5 degrees stimulus evoked no response in eight cases, proving the area of the hole was nonfunctional. A response was recorded in the four other cases, where the dimension of the holes was less than 2 degrees. The results of this scanning laser ophthalmoscopic assessment demonstrated a precise evaluation of the residual macular function in the cases of full-thickness macular holes.
一项研究旨在验证在12只眼睛进行黄斑裂孔手术前使用扫描激光检眼镜进行的功能检查:评估包括眼底检查、一项功能检查,该检查可评估视网膜优先低视力、视力并记录视觉诱发电位。通过呈现一个小正方形区域来评估视网膜优先位点,通过校准数字来确定视力。视觉诱发电位由三个交替的棋盘格(方格大小,30',2Hz)诱发,这些棋盘格以裂孔为中心,以6.5×6.5度、2.5×2.5度和6.5×6.5度的视角观察,中心排除2.5×2.5度。扫描激光检眼镜观察到的眼底外观包括与裂孔对应的清晰中央盘,周围是非常暗的环,伴有第二个边缘不清晰、较暗的环。1例视力为20/70的患者注视不稳定。在11例患者中,注视定位于视网膜上方,视力优于20/70。12只眼中均能分辨出由6.5×6.5度诱发的视觉诱发电位;11例能分辨出环形刺激诱发的视觉诱发电位。2.5×2.5度的刺激在8例中未诱发反应,证明裂孔区域无功能。在其他4例裂孔尺寸小于2度的病例中记录到了反应。这项扫描激光检眼镜评估的结果表明,在全层黄斑裂孔病例中,对黄斑残余功能进行了精确评估。