This paper presents a strategy for automatic control of induced paralysis using vecuronium bromide during surgery. The controller is self-tuning and adapts to inter-patient and intra-patient response variations while optimizing the output variance and infusion rate. In particular, the controller is capable of accommodating the variations of pure time delays in patient response. The performance of the controller is evaluated using an experimentally derived pharmacokinetic and nonlinear pharmacodynamic model of patient response. The results indicate that the controller provides robust regulation of the paralysis level with no output offset.

摘要

本文提出了一种在手术期间使用维库溴铵自动控制诱导性麻痹的策略。该控制器具有自整定功能,能适应患者之间和患者自身反应的变化,同时优化输出方差和输注速率。特别地,该控制器能够适应患者反应中纯时间延迟的变化。使用通过实验得出的患者反应的药代动力学和非线性药效学模型对控制器的性能进行评估。结果表明,该控制器能对麻痹水平进行稳健调节,且无输出偏移。