Suppr超能文献

12种软性义齿衬垫材料的吸附与溶解性

Sorption and solubility of 12 soft denture liners.

作者信息

Kawano F, Dootz E R, Koran A, Craig R G

机构信息

School of Dentistry, University of Michigan, Ann Arbor.

出版信息

J Prosthet Dent. 1994 Oct;72(4):393-8. doi: 10.1016/0022-3913(94)90559-2.

Abstract

The long-term stability of a soft denture liner depends to a large extent on the sorption and solubility of the liner. Because sorption and solubility are accompanied by a volumetric change, bacterial infestation, hardening, and color change, it is a physical property of importance. The purpose of this investigation was to determine the sorption and solubility of 12 soft denture liners (Verno-Soft, Super Soft, ProTech, Soft-Pak, Flexor, Novus, Molloplast-B, Durosoft, Justi Soft, Velvesoft, VinaSoft and Prolastic). They include nine copolymers, two silicones and one polyphosphazene fluoroelastomer. The sorption and solubility test was performed as outlined in American Dental Association (ADA) specification 12 for denture base polymers. Five specimens of each material were tested and data were collected at 1 week, 1 month, 3 months, 6 months, and 1 year. Sorption data varied from 0.2 to 5.6 mg/cm2 at 1 week; 0.3 to 12.5 mg/cm2 at 1 month; 0.1 to 22.0 mg/cm2 at 3 months; 0.1 to 13.6 mg/cm2 at 6 months; and 0.1 to 35.7 mg/cm2 at 12 months. Solubility data varied from 0.0 to 0.4 mg/cm2 at 1 week; 0.1 to 0.8 mg/cm2 at 1 month; +0.1 to 1.2 mg/cm2 at 3 months; 0.0 to 1.9 mg/cm2 at 6 months; and +0.2 to 2.3 mg/cm2 at 1 year. A statistical analysis of the data by two-way ANOVA and calculated Tukey intervals showed significant differences between materials at all time intervals. The results of this study have clinical implications because the sorption and solubility may affect the long-term life expectancy of the soft denture liner.

摘要

软性义齿衬垫的长期稳定性在很大程度上取决于衬垫的吸附性和溶解性。由于吸附和溶解伴随着体积变化、细菌滋生、硬化以及颜色改变,所以这是一项重要的物理特性。本研究的目的是测定12种软性义齿衬垫(Verno-Soft、Super Soft、ProTech、Soft-Pak、Flexor、Novus、Molloplast-B、Durosoft、Justi Soft、Velvesoft、VinaSoft和Prolastic)的吸附性和溶解性。它们包括9种共聚物、2种硅酮和1种聚磷腈氟弹性体。吸附和溶解性测试按照美国牙科协会(ADA)义齿基托聚合物规范12中所述进行。每种材料测试5个样本,并在1周、1个月、3个月、6个月和1年时收集数据。1周时吸附数据在0.2至5.6mg/cm²之间;1个月时在0.3至12.5mg/cm²之间;3个月时在0.1至22.0mg/cm²之间;6个月时在0.1至13.6mg/cm²之间;12个月时在0.1至35.7mg/cm²之间。溶解性数据1周时在0.0至0.4mg/cm²之间;1个月时在0.1至0.8mg/cm²之间;3个月时在+0.1至1.2mg/cm²之间;6个月时在0.0至1.9mg/cm²之间;1年时在+0.2至2.3mg/cm²之间。通过双向方差分析对数据进行统计分析并计算Tukey区间,结果显示在所有时间间隔内不同材料之间均存在显著差异。本研究结果具有临床意义,因为吸附性和溶解性可能会影响软性义齿衬垫的长期使用寿命。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验