Yoshinari M, Dérand T
Department of Dental Materials Science, Tokyo Dental College, Chiba, Japan.
Int J Prosthodont. 1994 Jul-Aug;7(4):329-38.
The fracture strengths of four types of all-ceramic premolar crowns (conventional Vita-Dur, In-Ceram, Dicor, and IPS-Empress) were compared after a preload cycling in aqueous atmosphere. Preload cycling significantly decreased the strength of Vita-Dur crowns. Fracture strength of Vita-Dur crowns was improved when they were luted with either polyalkenoate or adhesive resin cement. The average (standard deviation) of load to fracture of ceramic crowns luted using zinc phosphate cement and after applied preload cycling in distilled water were: Vita Dur, 770 (237) N; Vita In-Ceram, 1060 (341) N; Dicor, 840 (226) N; and IPS-Empress: 891 (185) N. The In-Ceram crowns fractured in two modes: complete fractures at 1276 (207) N; and fractures with the core remaining intact at 808 (292) N.
在水气氛中进行预加载循环后,比较了四种类型的全瓷前磨牙冠(传统的维他 - 杜尔、In-Ceram、Dicor和IPS-Empress)的断裂强度。预加载循环显著降低了维他 - 杜尔冠的强度。当用聚羧酸酯或粘结树脂粘结剂粘结维他 - 杜尔冠时,其断裂强度得到提高。使用磷酸锌粘结剂粘结并在蒸馏水中进行预加载循环后,陶瓷冠的平均(标准差)断裂载荷为:维他 - 杜尔,770(237)N;维他In-Ceram,1060(341)N;Dicor,840(226)N;以及IPS-Empress:891(185)N。In-Ceram冠有两种断裂模式:在1276(207)N时完全断裂;在808(292)N时核心保持完整的断裂。