通过双侧颈内静脉样本研究脑静脉血氧饱和度。

Cerebral venous oxygen saturation studied with bilateral samples in the internal jugular veins.

作者信息

Stocchetti N, Paparella A, Bridelli F, Bacchi M, Piazza P, Zuccoli P

机构信息

1st Department of Anesthesia and Intensive Care, Hospital of Parma, Italy.

出版信息

Neurosurgery. 1994 Jan;34(1):38-43; discussion 43-4.

PMID:8121568
Abstract

The current literature reports many measurements (arteriovenous oxygen content difference and cerebral metabolic rate of oxygen, etc.) with samples from the internal jugular veins (IJs), obtained from either side of the neck, based on the assumption that a reliable sample of mixed venous blood can be drawn. We compared oxygen saturation in both IJs in 32 patients with head injuries to establish the similarities or discrepancies in the two veins. Both IJs were cannulated with 20-G catheters; in five patients, a fiberoptic catheter was used to obtain a continuous recording of the hemoglobin saturation. Blood samples were taken simultaneously from the two IJs and immediately processed; the total number of samples processed was 342, with an average of 5.34 paired samples from each patient. The mean and the standard deviation of the differences between the saturation of the two IJs were, respectively, 5.32 and 5.15. Fifteen patients showed differences greater than 15% in hemoglobin saturation; three more patients showed differences greater than 10% at some point during the investigation. Ultimately, only eight patients had differences of less than 5%. No relationship was found among the computed tomographic scan data and the pattern of hemoglobin saturation detected. Therefore, we were not able to identify the side more appropriate for monitoring in patients with bilateral, predominantly monolateral, cortical, or deeply located lesions.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

当前文献报道了许多基于可以抽取可靠的混合静脉血样本这一假设,从颈部两侧的颈内静脉(IJ)采集样本进行的测量(动静脉氧含量差和脑氧代谢率等)。我们比较了32例头部受伤患者双侧颈内静脉的氧饱和度,以确定两条静脉之间的异同。双侧颈内静脉均用20G导管插管;5例患者使用光纤导管连续记录血红蛋白饱和度。同时从双侧颈内静脉采集血样并立即进行处理;共处理血样342份,平均每位患者有5.34对样本。双侧颈内静脉饱和度差异的均值和标准差分别为5.32和5.15。15例患者的血红蛋白饱和度差异大于15%;另有3例患者在调查期间的某些时间点差异大于10%。最终,只有8例患者的差异小于5%。未发现计算机断层扫描数据与检测到的血红蛋白饱和度模式之间存在关联。因此,我们无法确定对于双侧、主要为单侧、皮质或深部病变的患者,哪一侧更适合进行监测。(摘要截短于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验