Grassi W, Tittarelli E, Pirani O, Avaltroni D, Cervini C
Department of Rheumatology, University of Ancona, Italy.
Scand J Rheumatol. 1993;22(5):243-7. doi: 10.3109/03009749309095131.
To evaluate the ability of ultrasonography with high frequency transducer (13-MHz) in detecting metacarpophalangeal (MCP) joint abnormalities, 20 patients with rheumatoid arthritis (RA) and a symptomatic involvement of MCP joints were studied. Twenty healthy subjects served as controls. In all RA patients, ultrasonography clearly demonstrated one or more soft tissue and/or bone abnormalities. Sixteen patients (80%) had joint cavity widening because of effusion (1 case), synovial thickening (7 cases), and joint effusion with synovial thickening (8 cases). Loss of definition of the metacarpal articular cartilage was observed in 17 cases (85%). Sixteen (80%) had bone erosions and 9 (45%) showed a definite widening of the flexor tendons sheath. Margin irregularities of the extensor and flexor tendons were respectively visualized in 7 (35%) and in 8 (40%) cases. An extensor tendon rupture was observed in 2 cases (10%). Ultrasound examination by 13-MHz transducer appears to increase the accuracy of MCP joints evaluation in RA with respect to conventional radiography. It can be recommended as the first investigation in the assessment of soft tissue involvement in RA patients.
为评估高频探头(13兆赫)超声检查检测掌指关节(MCP)异常的能力,对20例患有类风湿关节炎(RA)且有MCP关节症状性受累的患者进行了研究。20名健康受试者作为对照。在所有RA患者中,超声检查清楚地显示出一处或多处软组织和/或骨骼异常。16例患者(80%)因积液(1例)、滑膜增厚(7例)以及积液伴滑膜增厚(8例)导致关节腔增宽。17例(85%)观察到掌骨关节软骨轮廓不清。16例(80%)有骨质侵蚀,9例(45%)显示屈肌腱鞘明显增宽。分别在7例(35%)和8例(40%)中观察到伸肌腱和屈肌腱边缘不规则。2例(10%)观察到伸肌腱断裂。与传统X线摄影相比,13兆赫探头的超声检查似乎提高了RA患者MCP关节评估的准确性。它可被推荐作为评估RA患者软组织受累情况的首选检查方法。