Suppr超能文献

使用单克隆抗体的时间分辨荧光免疫测定法快速鉴定4型副流感病毒和腮腺炎病毒。

Time-resolved fluoroimmunoassays with monoclonal antibodies for rapid identification of parainfluenza type 4 and mumps viruses.

作者信息

Hierholzer J C, Bingham P G, Castells E, Coombs R A

机构信息

Division of Viral and Rickettsial Diseases, Center for Infectious Diseases, Centers for Disease Control, Atlanta, Georgia.

出版信息

Arch Virol. 1993;130(3-4):335-52. doi: 10.1007/BF01309665.

Abstract

Monoclonal antibodies were prepared to the F and M proteins of parainfluenza 4A and 4B and to mumpsvirus to obtain reagents that could be configured into type-specific yet broadly-reactive IFA, EIA, and TR-FIA tests. Several antibodies to parainfluenza 4A also detected subtype 4B, although to a somewhat lower signal, and thus were well suited to generic parainfluenza type 4 tests that were comparable to similar tests previously described for parainfluenza types 1, 2, and 3. Monoclonals to subtype 4B were less able to detect 4A because of high background problems in one or another test. Monoclonals to mumpsvirus F protein were completely type-specific. These antibodies were screened by IFA and EIA for broad reactivity with diverse strains of each virus and were configured into optimized EIA and TR-FIA tests. The all-monoclonal tests were then compared to polyclonal tests in terms of their ability to detect virus in clinical specimens. The all-monoclonal TR-FIA was uniformly the most sensitive, detecting virus in 80% of culture-positive parainfluenza 4A specimens, 67% of parainfluenza 4B specimens, and 90% of mumps specimens, compared to 40-67% for the monoclonal EIA tests and 33-60% for the polyclonal EIA tests. For parainfluenza 4 TR-FIA, mean P/N values were 379 for subtype 4A cell culture fluids (228 for subtype 4B cultures) and 57 for 4A clinical specimens (43 for 4B specimens). For mumpsvirus TR-FIA, mean P/N values were 27 for culture fluids and 32 for clinical specimens. The sensitivities of the TR-FIA were determined with purified virus to be 0.28 ng virus per well for parainfluenza 4A and 0.70 ng virus per well for mumpsvirus.

摘要

制备了针对副流感4A和4B型F蛋白以及腮腺炎病毒的单克隆抗体,以获得可配置成型特异性但具有广泛反应性的免疫荧光分析(IFA)、酶免疫分析(EIA)和时间分辨荧光免疫分析(TR-FIA)检测试剂。几种针对副流感4A型的抗体也能检测到4B亚型,尽管信号稍低,因此非常适合用于通用的4型副流感检测,这些检测与先前针对1、2和3型副流感描述的类似检测相当。由于在一种或另一种检测中存在高背景问题,4B亚型的单克隆抗体检测4A型的能力较弱。针对腮腺炎病毒F蛋白的单克隆抗体具有完全的型特异性。通过IFA和EIA筛选这些抗体与每种病毒的不同菌株的广泛反应性,并将其配置成优化的EIA和TR-FIA检测。然后将全单克隆检测与多克隆检测在检测临床标本中病毒的能力方面进行比较。全单克隆TR-FIA始终是最敏感的,在80%的培养阳性副流感4A标本、67%的副流感4B标本和90%的腮腺炎标本中检测到病毒,相比之下,单克隆EIA检测为40 - 67%,多克隆EIA检测为33 - 60%。对于副流感4型TR-FIA,4A亚型细胞培养液的平均P/N值为379(4B亚型培养物为228),4A临床标本为57(4B标本为43)。对于腮腺炎病毒TR-FIA,培养液的平均P/N值为27,临床标本为32。用纯化病毒测定TR-FIA对副流感4A的灵敏度为每孔0.28 ng病毒,对腮腺炎病毒为每孔0.70 ng病毒。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验