Suppr超能文献

Femoral neck preservation in total hip replacement.

作者信息

Pipino F, Molfetta L

机构信息

Istituto di I Clinica Ortopedica, Università di Bari.

出版信息

Ital J Orthop Traumatol. 1993;19(1):5-12.

PMID:8567257
Abstract

Preservation of the femoral neck in hip arthroplasty creates a particular biomechanical situation which is clearly different from what is found even after partial neck removal. The femoral neck consists in fact of a "cylinder of cortical bone" that can be used as the "base" for anchoring the stem to the femur, in contrast to the press-fit procedure or other solutions. The mechanical and biological advantages are as follows: 1) Primary triplanar stem stability, in particular rotational stability. Rotational movements of the stem are blocked by the tough lateral cortical cylinder of the neck. Resistance to varus-valgus stress and collapse is also increased vertically and frontally. 2) Proximal cortical fixation. Primary fixation of the stem is provided by the neck cortex, whereas its mid-distal part is merely held by the metaphyseal cancellous bone and the tip is undersized with respect to the medullary canal. 3) Stress loads distributed along physiological lines of stress. Retention of the neck permits preservation of the trabecular systems, along which the stress is distributed towards the diaphysis and the greater trochanter. 4) Elasticity of the bone-prosthesis system. Most of the stem is contained within the metaphyseal cancellous bone that lies between the prosthesis and the cortical bone, creating a bone-prosthesis module with variable and integrated elasticity. 5) Preservation of the bone-stock. The amount of residual bone following implant of the prosthesis increases, not only because of the presence of the femoral neck, but also as a result of the preservation of most of the metaphyseal cancellous bone. There is therefore greater bone-ingrowth, which is also favoured by the fewer changes in the endosteal blood supply. 6) Prosthesis revision is simpler, since the stem can easily be removed and a second neck resection performed. Our clinical and experimental studies, together with those of Freeman et al., confirm that the femoral neck is present for a long time after implant. Finally, we report a study of 200 prostheses with a follow-up of 1 to 6 years, demonstrating neck reabsorption in only 1% of the cases.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验