PURPOSE

The primary purpose of this investigation was to validate anatomically, if possible, the Spaeth gonioscopic grading system.

METHODS

The gonioscopic appearance of the anterior chamber angle of 22 patients was described, using a Zeiss 4-mirror gonioscopic lens; the angle was graded according to the Spaeth gonioscopic grading system (SGGS) previously described elsewhere. This system provides a more comprehensive characterization of the angle than other methods, including the site of iris insertion, the angular approach to the recess and the curvature of the peripheral iris. The same patients were then evaluated with biomicroscopic ultrasound examination of the anterior segment; the nature of the anterior chamber angle was described independently by two observers. The two methods of characterizing the anterior chamber angle were then compared.

RESULTS

There was a high correlation between the two different methods of characterizing the anterior chamber angle. Ultrasound biomicroscopy had limitations relating to inability to distinguish between iris-cornea apposition and iris-cornea adhesion, and to exact location of the posterior trabecular meshwork. The angularity of the approach to the anterior chamber angle using the SGGS tended to be underestimated by about 5 degrees. Other aspects showed high correlation.

CONCLUSION

The SGGS appears to be an accurate method of characterizing the anatomic appearance of the anterior chamber angle in patients. It also provides a more comprehensive description of the angle that other grading systems.

摘要

目的

本研究的主要目的是尽可能从解剖学角度验证斯派思前房角镜分级系统。

方法

使用蔡司四镜前房角镜描述22例患者前房角的前房角镜表现;根据先前在其他地方描述的斯派思前房角镜分级系统(SGGS)对前房角进行分级。该系统比其他方法能更全面地描述前房角,包括虹膜附着部位、进入房角隐窝的角度以及周边虹膜的曲率。然后对同一组患者进行前段生物显微镜超声检查;由两名观察者独立描述前房角的情况。随后比较两种描述前房角的方法。

结果

两种不同的描述前房角的方法之间存在高度相关性。超声生物显微镜检查存在局限性,无法区分虹膜 - 角膜贴附与虹膜 - 角膜粘连,也无法确定后小梁网的确切位置。使用SGGS测量进入前房角的角度往往被低估约5度。其他方面显示出高度相关性。

结论

SGGS似乎是一种准确描述患者前房角解剖外观的方法。它对前房角的描述也比其他分级系统更全面。