Suppr超能文献

正畸弹性结扎圈的力衰减与变形

Force decay and deformation of orthodontic elastomeric ligatures.

作者信息

Taloumis L J, Smith T M, Hondrum S O, Lorton L

机构信息

U.S. Army Dental Corps, Fort George G. Meade, Md., USA.

出版信息

Am J Orthod Dentofacial Orthop. 1997 Jan;111(1):1-11. doi: 10.1016/s0889-5406(97)70295-6.

Abstract

This study evaluated commercially available molded gray elastomeric ligatures from seven companies for force decay, dimensional change, and the relationship between ligature dimension and force. The initial wall thickness, inside diameter, outside diameter, and force levels of each ligature were measured. Three of four test groups of ligatures were stretched over stainless steel dowels with a circumference approximating that of a large orthodontic twin bracket. Test group 1 was kept at room temperature and humidity for 28 days and test group 2 in a synthetic saliva bath at 37 degrees C, pH 6.84 for 28 days. The residual forces and dimensional changes were measured. The third test group was placed in a synthetic saliva bath at 37 degrees C, pH 6.84, and force levels recorded at initial, 24 hours, 7 days, 14 days, and 28 days. The fourth test group of unstretched samples was placed in a synthetic saliva bath at 37 degrees C, pH 6.84 for 28 days to evaluate dimensional changes due solely to moisture sorption. The results for stretched samples in a simulated oral environment revealed the following: (1) Moisture and heat had a pronounced effect on force decay and permanent deformation, (2) a positive correlation existed between the wall thickness and force, (3) a negative correlation existed between the inside diameter and force, (4) a weak correlation existed between outside diameter and force, (5) the greatest force loss occurred in the first 24 hours and the decay pattern was similar for all ligatures tested, and (6) unstretched ligatures absorbed moisture in the range of 0.060% to 3.15%. The ligatures tested appear to be suitable for use during initial aligning and leveling. However, the rapid force loss and permanent deformation of these products may preclude their use for rotational and torque corrections.

摘要

本研究评估了七家公司生产的市售模制灰色弹性结扎丝的力衰减、尺寸变化以及结扎丝尺寸与力之间的关系。测量了每种结扎丝的初始壁厚、内径、外径和力水平。四组结扎丝测试样本中的三组被拉伸套在不锈钢销钉上,销钉的周长近似于大型正畸孪生托槽的周长。测试组1在室温和湿度条件下放置28天,测试组2在37摄氏度、pH值为6.84的人工唾液浴中放置28天。测量残余力和尺寸变化。第三测试组置于37摄氏度、pH值为6.84的人工唾液浴中,并在初始、24小时、7天、14天和28天记录力水平。第四组未拉伸样本置于37摄氏度、pH值为6.84的人工唾液浴中28天,以评估仅由吸湿引起的尺寸变化。模拟口腔环境中拉伸样本的结果显示如下:(1)水分和热量对力衰减和永久变形有显著影响;(2)壁厚与力之间存在正相关;(3)内径与力之间存在负相关;(4)外径与力之间存在弱相关;(5)最大的力损失发生在最初24小时内,且所有测试结扎丝的衰减模式相似;(6)未拉伸的结扎丝吸湿范围在0.060%至3.15%之间。所测试的结扎丝似乎适用于初始排齐和平整阶段。然而,这些产品的快速力损失和永久变形可能使其不适合用于扭转和转矩矫正。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验