Clinical performance of leukocyte differential on the new Roche Cobas Vega haematological analyzer.

作者信息

Lippi G, Nicoli M, Modena N, Guidi G

机构信息

Laboratorio di Analisi Chimico Cliniche e Microbiologiche, Istituto di Chimica e Microscopia Clinica dell'Università di Verona, Valeggio s/M (VR), Italy.

出版信息

Eur J Clin Chem Clin Biochem. 1997 Feb;35(2):105-10.

PMID:9056752
Abstract

The Roche Cobas Vega is a five-part differential haematological analyzer evolving from the former Cobas Helios, Argos and Micros. As the leukocyte differential of Cobas Vega displays several interesting features, we analyzed its clinical performance and compared it either to three other commercial haematological analyzers (Technicon-Bayer H*2, Coulter STKS and Abbott CD-3500) or to the manual reference method, as described in the National Committee for Clinical Laboratory Standards (NCCLS) H20-A protocol. Within- and between-batch coefficients of variations (CVs) of the white blood cell differential were satisfactory and close, or even better than the ones reported for the other instruments: 0.81% (neutrophils), 1.87% (lymphocytes), 6.76% (monocytes), 7.73% (eosinophils) and 22.55% (basophils). The identification of abnormalities in the white blood cell differential was obtained either on the basis of the instrument-specific ranges or on the generation of one or more flags by comparison with results of the manual reference method. The Vega demonstrated remarkable performance in terms of specificity (90.0%), sensitivity (91.6%) and both positive (97.7%) and negative (69.1%) predictive values; likewise, the global efficiency was the best (90.3%) among the analyzers we evaluated. The flags generated in the presence of morphological abnormalities of the samples displayed excellent sensitivity (from 88.9% to 100%), specificity (from 93.5% to 98.3%) and satisfactory positive (from 51.1% to 66.7%) and negative (from 98.3% to 100%) predictive values. We conclude that the analytical performance of the new Cobas Vega haematological analyzer can significantly improve the identification of various haematological abnormalities as an important contribution to the accuracy is provided by the new staining for granulocytes.

摘要

相似文献

1
Clinical performance of leukocyte differential on the new Roche Cobas Vega haematological analyzer.
Eur J Clin Chem Clin Biochem. 1997 Feb;35(2):105-10.
2
Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500.雅培Cell Dyn 3500的完整分析和诊断性能。
Panminerva Med. 1998 Jun;40(2):116-25.
3
Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.自动化五分类白细胞计数。血液分析仪Sysmex SE - 9000、Sysmex NE - 8000和库尔特STKS软件生成的白细胞可疑标记的效率。
Arch Pathol Lab Med. 1997 Jun;121(6):573-7.
4
Comparison of performance for leukocyte differential counting of the Technicon H6000 system with a manual reference method using the NCCLS standard.使用NCCLS标准,将Technicon H6000系统白细胞分类计数性能与手工参考方法进行比较。
Blood Cells. 1985;11(2):257-79.
5
Evaluation and performance of the Coulter STKS.库尔特STKS的评估与性能
Eur J Clin Chem Clin Biochem. 1993 Mar;31(3):179-86.
6
[Comparative and simultaneous evaluation of three automated counters in hematology: Coulter STKS, Sysmex NE 8000, Technicon H-2].血液学中三种自动血细胞计数器的比较及同步评估:库尔特STKS、希森美康NE 8000、Technicon H-2
Ann Biol Clin (Paris). 1993;51(6):627-35.
7
Evaluation of the leukocyte differential flags on an hematologic analyzer. The Cobas Argos 5 Diff.血液分析仪上白细胞分类标记的评估。科巴斯阿戈斯5分类仪。
Am J Clin Pathol. 1995 Nov;104(5):495-502. doi: 10.1093/ajcp/104.5.495.
8
[New technology of automated blood cell differential counting].[自动血细胞分类计数新技术]
Rinsho Byori. 1998 Apr;46(4):361-6.
9
Evaluation of the Abbott CELL-DYN 4000 hematology analyzer.雅培CELL-DYN 4000血液分析仪评估
Am J Clin Pathol. 2000 Apr;113(4):497-505. doi: 10.1309/L7LC-6KKJ-12G2-196W.
10
Evaluation of the ABX Cobas Vega automated hematology analyzer and comparison with the Coulter STKS.ABX Cobas Vega全自动血液分析仪的评估及与库尔特STKS的比较。
Hematol Cell Ther. 1997 Jun;39(3):149-58. doi: 10.1007/s00282-997-0149-6.

引用本文的文献

1
How Reproducible Is the Data from Sysmex DI-60 in Leukopenic Samples?Sysmex DI-60在白细胞减少样本中的数据可重复性如何?
Diagnostics (Basel). 2021 Nov 23;11(12):2173. doi: 10.3390/diagnostics11122173.