Taylor T V, Bone D, Torrance B
Br J Surg. 1977 Oct;64(10):702-8. doi: 10.1002/bjs.1800641006.
Using 98Tcm a non-invasive test of gastric function has been developed which completely obviates the need for a nasogastric tube and which adds to the accuracy of existing tests by overcoming losses due to incomplete aspiration or gastric emptying. 99Tcm is handled by the stomach like Cl-, the gastric secretion of which is equal to that of H+. The value of the pentagastrin stimulation test in the presence of varied gastric pathology is discussed in relation to 50 patients. Other possible diagnostic uses of the test are evaluated and a method of carrying out an insulin test by a modification of the technique is described.
利用98锝开发了一种胃功能的非侵入性检测方法,该方法完全无需使用鼻胃管,并且通过克服因抽吸不完全或胃排空导致的损失,提高了现有检测方法的准确性。99锝在胃内的处理方式与氯离子相同,其胃分泌量与氢离子相等。结合50例患者讨论了在各种胃部病变情况下五肽胃泌素刺激试验的价值。评估了该检测方法的其他可能诊断用途,并描述了一种通过改进技术进行胰岛素检测的方法。