Suppr超能文献

用对流免疫电泳法检测荚膜组织胞浆菌沉淀抗体。

Detection of precipitating antibodies to Histoplasma capsulatum by counterimmunoelectrophoresis.

作者信息

Picardi J L, Kauffman C A, Schwarz J, Phair J P

出版信息

Am Rev Respir Dis. 1976 Jul;114(1):171-6. doi: 10.1164/arrd.1976.114.1.171.

Abstract

The technique of counterimmunoelectrophoresis was evaluated for its usefulness in the detection of precipitating antibodies to Histoplasma capsulatum, designated h and m precipitin bands. Forty-four patients with active histoplasmosis had either m bands or both h and m bands. The h precipitin band occurred primarily in patients with disseminated disease, chronic pulmonary disease, or mediastinal lymphadenopathy of several months' duration; with resolution of the infection, this antibody disappeared. The m band appeared earlier in the course of histoplasmosis and persisted for months to years after resolution of the infection. Antibodies detected by counterimmunoeelectrophoresis were in the immunoglobin G class and were more specific for histoplasmosis than those detected by the complement fixation test. Only one false positive h band occurred in a total of 81 sera tested (specimens from 24 healthy control subjects and 57 patients with other diseases). Counterimmunoelectrophoresis was both more sensitive and quicker than immunodiffusion at detecting h and m antibodies. Combining this assay with standard complement fixation tests and fungal culture methods should lead to the accurate, rapid diagnosis of histoplasmosis.

摘要

对流免疫电泳技术被评估其在检测针对荚膜组织胞浆菌沉淀抗体(即h和m沉淀带)方面的实用性。44例活动性组织胞浆菌病患者出现了m带或h和m带。h沉淀带主要出现在播散性疾病、慢性肺部疾病或持续数月的纵隔淋巴结病患者中;随着感染的消退,这种抗体消失。m带出现在组织胞浆菌病病程早期,感染消退后持续数月至数年。对流免疫电泳检测到的抗体属于免疫球蛋白G类,比补体结合试验检测到的抗体对组织胞浆菌病更具特异性。在总共检测的81份血清(来自24名健康对照受试者和57名其他疾病患者的标本)中仅出现1条假阳性h带。在检测h和m抗体方面,对流免疫电泳比免疫扩散更敏感、更快。将该检测方法与标准补体结合试验和真菌培养方法相结合应能实现组织胞浆菌病的准确、快速诊断。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验