Accuracy and precision of access recirculation measurements by the hemodynamic recirculation monitor.

作者信息

Lindsay R M, Blake P G, Malek P, Posen G, Martin B, Bradfield E

机构信息

Optimal Dialysis Research Unit, London Health Sciences Centre, Ontario, Canada.

出版信息

Am J Kidney Dis. 1998 Feb;31(2):242-9. doi: 10.1053/ajkd.1998.v31.pm9469494.

DOI:10.1053/ajkd.1998.v31.pm9469494
PMID:9469494
Abstract

The hemodynamic monitor (HDM) is a device that uses magnetic principles to accurately measure access recirculation during hemodialysis. The measurement is based on differential conductivity between arterial and venous blood flow rates in the dialysis blood tubing sets. One milliliter of hypertonic saline is injected into the venous line of the blood tubing set as a conductivity "tracer." As the tracer enters the patient, the presence of access recirculation causes a percentage of the hypertonic saline to recirculate into the arterial line and is detected and quantified by the HDM; the percentage of access recirculation is calculated in under 1 minute. Clinical studies were performed in two centers on 106 patients with various forms of blood access (eg, arteriovenous fistulae, Gore-tex grafts [WL Gore and Associates, Flagstaff, AZ], Permcaths [Quinton Instrument Co, Bothell, WA], subclavian catheters). Access recirculation was detected under routine dialysis conditions in only 13 patients. In the remaining cases, attempts at inducing access recirculation were made by reversing the arterial and venous lines and/or increasing the blood pump to its maximum sustainable rate for a given patient. A 15-minute protocol was then instituted. Three blood samples (arterial, venous, and "peripheral" [stop-flow technique]) were first obtained to determine urea measurements and for subsequent calculation of access recirculation; immediately afterward, an HDM recirculation measurement was recorded to allow correlation of urea and HDM access recirculation results (accuracy). Two further HDM access recirculation measurements were made to analyze the precision or repeatability of the HDM test. This protocol was attempted up to three times in each patient on different dialysis days. Two hundred fifty-nine studies were made, and a strong linear correlation was obtained between urea and HDM results (r = 0.94, slope 0.95) over a range of access recirculation (5% to 60%) demonstrating accuracy. Repeated HDM access recirculation results showed a characteristic SD of 1.8% over the whole range of values, demonstrating a precision superior to the 6% expected using the urea method. When zero access recirculation was indicated by the HDM, "ground truth" tests were performed by injecting 1 mL of hypertonic saline (HS) into one injection port of the blood tubing set then 0.1 mL of HS into the other to simulate 10% access recirculation; the mean results were 9.96%+/-1.59% (+/-SD; n = 93), confirming the accuracy of the method.

摘要

相似文献

1
Accuracy and precision of access recirculation measurements by the hemodynamic recirculation monitor.
Am J Kidney Dis. 1998 Feb;31(2):242-9. doi: 10.1053/ajkd.1998.v31.pm9469494.
2
Estimation of hemodialysis access blood flow rates by a urea method is a poor predictor of access outcome.通过尿素法估算血液透析通路的血流量,对通路预后的预测效果不佳。
ASAIO J. 1998 Nov-Dec;44(6):818-22. doi: 10.1097/00002480-199811000-00010.
3
Hemodialysis access blood flow rates can be measured by a differential conductivity technique and are predictive of access clotting.血液透析通路的血流量可通过微分电导率技术进行测量,并且能够预测通路的凝血情况。
Am J Kidney Dis. 1997 Oct;30(4):475-82. doi: 10.1016/s0272-6386(97)90304-8.
4
A comparison of methods for the measurement of hemodialysis access recirculation and access blood flow rate.血液透析通路再循环及通路血流量测量方法的比较
ASAIO J. 1998 Jan-Feb;44(1):62-7.
5
All currently used measurements of recirculation in blood access by chemical methods are flawed due to intradialytic disequilibrium or recirculation at low flow.目前所有通过化学方法测量血液通路中再循环的方法都存在缺陷,原因是透析过程中的不平衡或低流量时的再循环。
Am J Kidney Dis. 1998 Dec;32(6):1046-58. doi: 10.1016/s0272-6386(98)70082-4.
6
Blood recirculation in temporary central catheters for acute hemodialysis.急性血液透析临时中心静脉导管中的血液再循环
Clin Nephrol. 1996 May;45(5):315-9.
7
Direct determination of blood recirculation rate in hemodialysis by a conductivity method.通过电导率法直接测定血液透析中的血液再循环率。
ASAIO J. 1998 Jan-Feb;44(1):68-73.
8
Sensitivity and specificity of the thermodilution technique in detection of access recirculation.热稀释技术检测内瘘再循环的敏感性和特异性。
Nephron. 2000 Jun;85(2):134-41. doi: 10.1159/000045646.
9
Validation of haemodialysis recirculation and access blood flow measured by thermodilution.通过热稀释法测量的血液透析再循环和通路血流量的验证。
Nephrol Dial Transplant. 1999 Feb;14(2):376-83. doi: 10.1093/ndt/14.2.376.
10
[Recirculation of urea and dialysis efficiency using dual-lumen dialysis catheters in various locations: may the venous lumen of the catheter be used as the arterial lumen and vice versa?].[不同部位使用双腔透析导管时尿素的再循环及透析效率:导管的静脉腔可作为动脉腔使用,反之亦然吗?]
Lijec Vjesn. 2003 Jan-Feb;125(1-2):1-5.