Foster P J, Baasanhu J, Alsbirk P H, Munkhbayar D, Uranchimeg D, Johnson G J
Department of Preventive Ophthalmology, Institute of Ophthalmology, London, England.
Ophthalmology. 1998 Jun;105(6):969-73. doi: 10.1016/S0161-6420(98)96021-3.
The purpose of the study was to quantify the variation of central corneal thickness (CCT) in an east Asian population and to examine its relationship to estimates of intraocular pressure (IOP) made with an applanation tonometer.
The study design was a cross-sectional, population-based survey.
One thousand two-hundred forty-two residents of Hövsgöl Province, Mongolia, 10 to 87 years of age participated.
The CCT was measured using an optical pachymeter in all subjects. The IOP was measured using a, Goldmann-type applanation tonometer in subjects 40 years of age and older.
There was a highly significant decrease in CCT with age: 5 microns/decade in men and 6 microns/decade in women (both, P < 0.0001). A highly significant positive correlation was identified between IOP and CCT. Linear regression analysis suggests that between the ages of 40 and 80 years, an increase in CCT of 10 microns is associated with an increase in IOP measurements of 0.18 mmHg in right eyes (95% confidence interval, 0.12-0.25) and 0.24 mmHg in left eyes (95% confidence interval, 0.17-0.31). The authors calculate that interindividual differences in CCT may produce a difference in measured IOP of between 2.3 and 3.1 mmHg.
Variation in CCT is a significant source of variation in IOP measurements between individuals. The authors suggest that measurement of corneal thickness should be considered when assessing IOP as a risk factor for glaucoma in east Asians.
本研究旨在量化东亚人群中央角膜厚度(CCT)的变化,并探讨其与应用压平眼压计测量的眼压(IOP)估值之间的关系。
本研究设计为一项基于人群的横断面调查。
蒙古国色楞格省1242名年龄在10至87岁的居民参与了研究。
所有受试者均使用光学角膜厚度仪测量CCT。40岁及以上受试者使用戈德曼式压平眼压计测量IOP。
CCT随年龄增长显著降低:男性为5微米/十年,女性为6微米/十年(均P < 0.0001)。IOP与CCT之间存在高度显著的正相关。线性回归分析表明,在40至80岁之间,CCT增加10微米与右眼IOP测量值增加0.18 mmHg相关(95%置信区间,0.12 - 0.25),与左眼IOP测量值增加0.24 mmHg相关(95%置信区间,0.17 - 0.31)。作者计算得出,CCT的个体差异可能导致测量的IOP差异在2.3至3.1 mmHg之间。
CCT的变化是个体间IOP测量值变化的一个重要来源。作者建议,在评估东亚人群青光眼风险因素IOP时,应考虑测量角膜厚度。