Uchida K, Watanabe H, Aoki T, Nakamura K, Nakata H
Department of Radiology, University of Occupational and Environmental Health, Yahatanishi-ku, Japan.
J Digit Imaging. 1998 Aug;11(3):121-5. doi: 10.1007/BF03168735.
We evaluated the clinical utility of high data compression for computed radiography (CR) of the hand. Paired original and compressed CR images were obtained using an FCR 9000 system in 35 patients with various abnormalities of the hand. For the paired original and compressed images, we compared the depiction of the bone cortex, bone trabeculae, soft-tissue, and the margin of the abnormalities. The overall impressions for detectability of the abnormalities and for diagnostic capability were also evaluated. Poorer image quality of the compressed images was noted for most of the structures, but there was no significant difference between the original and compressed images as for the overall impressions for detectability of the abnormalities or for diagnostic capability. We conclude that a high data compression may be clinically acceptable with caution in radiography of the hand.