Lykke J, Kirstein A, Bagger J
Ortopaedkirurgisk afdeling, Amtssygehuset i Glostrup.
Ugeskr Laeger. 1998 Oct 26;160(44):6357-8.
A patient was transferred from Pakistan to a Danish orthopaedic ward. In Denmark he was tested MRSA-positive. Two months after he was discharged, similar MRSA strains were found in another patient. The two patients had been on the same ward for one week. All hygienic precautions had been taken. Staff and other patients on the ward at the relevant time all tested MRSA-negative.
一名患者从巴基斯坦转至丹麦的一个骨科病房。在丹麦,他的耐甲氧西林金黄色葡萄球菌检测呈阳性。他出院两个月后,在另一名患者身上发现了类似的耐甲氧西林金黄色葡萄球菌菌株。这两名患者曾在同一病房住过一周。已采取了所有卫生预防措施。相关时间在病房的工作人员和其他患者的耐甲氧西林金黄色葡萄球菌检测均为阴性。