Abstract

BACKGROUND

Because of recent technological advances, exercise testing laboratories now have the ability to use ramp protocols with treadmill exercise tests. Since the Bruce protocol is the most widely used treadmill protocol in clinical laboratories, a standardized ramp treadmill protocol was developed that corresponds to the speed and grade settings of the Bruce protocol at each 3-minute time interval. The purpose of this study was to evaluate the utility of using subject demographic and exercise test data to predict peak oxygen uptake (VO2peak) for tests conducted with the BSU/Bruce Ramp protocol.

METHODS

Maximal exercise tests were performed by 698 men and women using the BSU/Bruce Ramp protocol. Peak oxygen uptake was measured during all tests. Stepwise multiple regression analyses were used to predict VO2peak (mL.kg-1.min-1) from maximal treadmill test time and selected variables including age, gender, physical activity habits, and body weight.

RESULTS

Maximal test time was found to be the most potent predictor of VO2peak, accounting for 86% of the variance in peak aerobic power, with a standard error of estimate of 3.4 mL kg min-1. A multiple regression equation including age, gender, physical activity habits, and body weight resulted in a slightly improved prediction (R2 = 0.88; standard error of estimates = 3.1 mL kg min-1).

CONCLUSIONS

Peak oxygen uptake values can be predicted with reasonable accuracy from the BSU/Bruce Ramp protocol. The BSU/Bruce Ramp would be an excellent choice for laboratories desiring to use a ramp treadmill protocol because of the design of the protocol with identical workloads at equivalent time periods (3, 6, 9, 12, 15, 18, 21 minutes) as the commonly used Bruce protocol.

摘要

背景

由于近期的技术进步,运动测试实验室现在有能力在跑步机运动测试中使用递增式方案。由于布鲁斯方案是临床实验室中使用最广泛的跑步机方案,因此开发了一种标准化的递增式跑步机方案,该方案在每个3分钟时间间隔内对应于布鲁斯方案的速度和坡度设置。本研究的目的是评估使用受试者人口统计学和运动测试数据来预测采用BSU/布鲁斯递增式方案进行测试时的峰值摄氧量(VO2peak)的效用。

方法

698名男性和女性使用BSU/布鲁斯递增式方案进行了最大运动测试。在所有测试中测量了峰值摄氧量。采用逐步多元回归分析,根据最大跑步机测试时间以及包括年龄、性别、身体活动习惯和体重在内的选定变量来预测VO2peak(毫升·千克-1·分钟-1)。

结果

发现最大测试时间是VO2peak的最有力预测指标,占峰值有氧功率方差的86%,估计标准误差为3.4毫升·千克·分钟-1。一个包括年龄、性别、身体活动习惯和体重的多元回归方程导致预测略有改善(R2 = 0.88;估计标准误差 = 3.1毫升·千克·分钟-1)。

结论

采用BSU/布鲁斯递增式方案可以相当准确地预测峰值摄氧量值。对于希望使用递增式跑步机方案的实验室来说,BSU/布鲁斯递增式方案将是一个绝佳选择,因为该方案的设计在与常用的布鲁斯方案相同的时间段(3、6、9、12、15、18、21分钟)具有相同的工作量。