Kamal D S, Viswanathan A C, Garway-Heath D F, Hitchings R A, Poinoosawmy D, Bunce C
Glaucoma Unit, Moorfields Eye Hospital London.
Br J Ophthalmol. 1999 Mar;83(3):290-4. doi: 10.1136/bjo.83.3.290.
To determine whether analysis of sequential optic disc images obtained with the Heidelberg retina tomograph (HRT) is able to demonstrate optic disc change before the development of reproducible field defects in a group of ocular hypertensive (OHT) patients converting to early glaucoma.
Two groups were analysed: (1) 13 eyes of 13 OHT patients who subsequently developed reproducible field defects (converters); and (2) 13 eyes of 11 normal control subjects. Two sequential optic disc images were obtained using the HRT (median separation between images was 12 months for the converters and 13 months for the normals). The second image in the converter group was obtained before confirmed visual field loss. The optic disc variables were analysed both globally and segmentally using HRT software version 1.11. The Wilcoxon signed rank test was used to determine if there were any significant differences between the variables of the two image sets.
Significant optic disc change was demonstrated in the group of converters: (1) global variables: the cup area increased by 9.7%, the C/D area ratio increased by 10.5%, and the rim area decreased by 6.9%; (2) segmental variables: the superonasal cup area increased by 11.0%, the superonasal C/D area ratio increased 11.7%, and the inferonasal cup volume increased by 28.4%. The temporal rim volume decreased by 15.6%, the inferotemporal rim volume decreased by 23.6%, and the rim area in the superonasal and superotemporal segments decreased by 6.6% and 6.9% respectively.
Analysis of sequential optic disc images on the HRT allowed the detection of glaucomatous change before confirmed visual field change in a group of OHT patients converting to early glaucoma.
确定对使用海德堡视网膜断层扫描仪(HRT)获得的连续视盘图像进行分析,是否能够在一组眼压升高(OHT)且即将发展为早期青光眼的患者出现可重复性视野缺损之前,证实视盘的变化。
分析两组对象:(1)13例OHT患者的13只眼睛,这些患者随后出现了可重复性视野缺损(转变者);(2)11名正常对照者的13只眼睛。使用HRT获取两张连续的视盘图像(转变者组图像之间的中位间隔时间为12个月,正常组为13个月)。转变者组的第二张图像是在确认视野丧失之前获得的。使用HRT软件版本1.11对视盘变量进行整体和分段分析。采用Wilcoxon符号秩检验来确定两组图像变量之间是否存在任何显著差异。
在转变者组中证实了明显的视盘变化:(1)整体变量:杯盘面积增加了9.7%,杯盘面积比增加了10.5%,盘沿面积减少了6.9%;(2)分段变量:鼻上杯盘面积增加了11.0%,鼻上杯盘面积比增加了11.7%,鼻下杯盘体积增加了28.4%。颞侧盘沿体积减少了15.6%,颞下盘沿体积减少了23.6%,鼻上和颞上节段的盘沿面积分别减少了6.6%和6.9%。
对HRT上的连续视盘图像进行分析,能够在一组即将发展为早期青光眼的OHT患者出现视野变化之前检测到青光眼性变化。