Suppr超能文献

雅培LCx结核分枝杆菌连接酶链反应检测法的多中心评估。

Multicenter evaluation of the Abbott LCx Mycobacterium tuberculosis ligase chain reaction assay.

作者信息

Lumb R, Davies K, Dawson D, Gibb R, Gottlieb T, Kershaw C, Kociuba K, Nimmo G, Sangster N, Worthington M, Bastian I

机构信息

Infectious Diseases Laboratories, Institute of Medical and Veterinary Science, Adelaide, South Australia, Australia.

出版信息

J Clin Microbiol. 1999 Oct;37(10):3102-7. doi: 10.1128/JCM.37.10.3102-3107.1999.

Abstract

Four Australian hospital laboratories evaluated the performance of the Abbott LCx Mycobacterium tuberculosis assay with 2,347 specimens (2,083 respiratory and 264 nonrespiratory specimens) obtained from 1, 411 patients. A total of 152 specimens (6.5%) were culture positive for Mycobacterium tuberculosis complex (MTBC); of these, 79 (52%) were smear positive. After resolution of discrepant data, the overall sensitivity, specificity, and positive and negative predictive values for the LCx assay were 69.7, 99.9, 99.1, and 97.7% respectively. For smear-positive respiratory specimens that were culture positive for MTBC, the values were 98.5, 100, 100, and 98.4%, respectively, while the values for smear-negative respiratory specimens were 41.5, 99.9, 96.4, and 98%, respectively. Relative operating characteristic curves were constructed to demonstrate the relationship between sensitivity and specificity for a range of possible cutoff values in the LCx assay. These graphs suggested that the assay sensitivity for respiratory samples could be increased from 70.2 to 78.6%, while the specificity would be reduced from 99.9 to 99.4% by inclusion of a grey zone (i.e., LCx assay values of between 0.2 and 0.99). An algorithm is presented for the handling of specimens with LCx assay values within this grey zone.

摘要

四个澳大利亚医院实验室对雅培LCx结核分枝杆菌检测法的性能进行了评估,检测对象为从1411名患者身上获取的2347份标本(2083份呼吸道标本和264份非呼吸道标本)。共有152份标本(6.5%)结核分枝杆菌复合群(MTBC)培养呈阳性;其中,79份(52%)涂片呈阳性。在解决了有差异的数据后,LCx检测法的总体灵敏度、特异性、阳性预测值和阴性预测值分别为69.7%、99.9%、99.1%和97.7%。对于MTBC培养呈阳性的涂片阳性呼吸道标本,这些值分别为98.5%、100%、100%和98.4%,而涂片阴性呼吸道标本的值分别为41.5%、99.9%、96.4%和98%。构建了相对操作特征曲线,以展示LCx检测法在一系列可能的临界值下灵敏度和特异性之间的关系。这些图表表明,通过纳入一个灰色区域(即LCx检测值在0.2至0.99之间),呼吸道样本的检测灵敏度可从70.2%提高到78.6%,而特异性将从99.9%降至99.4%。本文给出了一种处理LCx检测值处于该灰色区域内标本的算法。

相似文献

引用本文的文献

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验