Suppr超能文献

采用快速免疫层析法检测尿样中的肺炎链球菌抗原。

Detection of Streptococcus pneumoniae antigen by a rapid immunochromatographic assay in urine samples.

作者信息

Domínguez J, Galí N, Blanco S, Pedroso P, Prat C, Matas L, Ausina V

机构信息

Servei de Microbiologia, Hospital Universitari Germans Trias i Pujol, Badalona, Facultat de Medicina de la Universitat Autònoma de Barcelona, Spain.

出版信息

Chest. 2001 Jan;119(1):243-9. doi: 10.1378/chest.119.1.243.

Abstract

STUDY OBJECTIVES

Evaluation of a newly available rapid (15 min) immunochromatographic membrane test (ICT) to detect Streptococcus pneumoniae in urine samples, in order to assess its utility in the diagnosis of bacteremic and nonbacteremic pneumococcal pneumonia.

DESIGN

Retrospective study.

SETTING

We studied urine samples from 51 patients with bacteremic and nonbacteremic pneumonia due to S pneumoniae diagnosed by blood culture and pneumococcal polysaccharide capsular antigen detection by counterimmunoelectrophoresis in urine samples, 16 patients with probable pneumococcal pneumonia, 71 patients with nonpneumococcal pneumonia, and 16 patients with pneumonia but no pathogen identified. Urine samples were collected and frozen at - 20 degrees C until used. The ICT test was performed following the instructions of the manufacturer.

MEASUREMENTS AND RESULTS

S. pneumoniae antigen was detected in 41 of 51 patients with pneumococcal pneumonia (80.4%); results were positive in 23 of 28 bacteremic cases (82.1%) and in 18 of 23 nonbacteremic cases (78.3%). From patients with a diagnosis of presumptive pneumococcal pneumonia, antigen was detected in seven urine samples (43.7%) and also in one case of the 16 patients with pneumonia but no pathogen identified. The specificity of the ICT test was 97.2%.

CONCLUSION

The ICT assay is a valuable tool for the diagnosis of pneumococcal pneumonia, especially for the nonbacteremic cases.

摘要

研究目的

评估一种新的快速(15分钟)免疫层析膜检测法(ICT),用于检测尿样中的肺炎链球菌,以评估其在诊断菌血症性和非菌血症性肺炎球菌肺炎中的效用。

设计

回顾性研究。

背景

我们研究了51例因肺炎链球菌导致菌血症性和非菌血症性肺炎患者的尿样,这些患者通过血培养以及尿样中肺炎球菌多糖荚膜抗原的对流免疫电泳检测确诊;16例可能患有肺炎球菌肺炎的患者;71例非肺炎球菌肺炎患者;以及16例患有肺炎但未鉴定出病原体的患者。收集尿样并在-20℃下冷冻保存直至使用。ICT检测按照制造商的说明进行。

测量与结果

51例肺炎球菌肺炎患者中有41例(80.4%)检测到肺炎链球菌抗原;28例菌血症病例中有23例(82.1%)结果呈阳性,23例非菌血症病例中有18例(78.3%)结果呈阳性。在诊断为疑似肺炎球菌肺炎的患者中,7份尿样(43.7%)检测到抗原,在16例患有肺炎但未鉴定出病原体的患者中也有1例检测到抗原。ICT检测的特异性为97.2%。

结论

ICT检测是诊断肺炎球菌肺炎的一项有价值的工具,尤其是对于非菌血症病例。