Jemt T, Henry P, Lindén B, Naert I, Weber H, Bergström C
Prosthetic Division, Brånemark Clinic, Public Dental Health, Göteborg, Sweden.
Int J Prosthodont. 2000 Jul-Aug;13(4):282-8.
The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks.
Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed.
Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design.
The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.
这项前瞻性多中心研究的目的是评估和比较激光焊接钛制种植体支持的固定局部义齿与传统铸造支架的临床性能。
42例部分牙列缺损患者植入了Brånemark系统种植体,并分为2组。A组患者一侧颌骨使用带有瓷贴面的传统铸造支架,另一侧使用带有低熔瓷的激光焊接钛支架。B组患者用钛支架义齿替换旧的种植体义齿。义齿植入后对患者进行3年随访。收集并分析临床和影像学数据。
3年后仅1枚种植体丢失,所有义齿仍在使用。两种支架设计显示出相似的临床性能,临床并发症较少。仅1枚基台螺钉(1%)和9个瓷牙单位(5%)发生断裂。4个义齿的金螺钉松动(6%)。在A组,两种义齿设计的边缘骨吸收相似,上颌和下颌的平均吸收分别为1.0 mm和0.3 mm。B组平均未观察到骨吸收。边缘骨吸收与义齿边缘位置或义齿设计之间未观察到显著相关性(P>0.05)。
3年后,在部分种植情况下,使用激光焊接钛支架似乎与传统铸造支架具有相似的临床性能。