Jemt Torsten, Henry Patrick, Lindén Bengt, Naert Ignace, Weber Heiner, Wendelhag Inger
The Brånemark Clinic, Public Dental Health, Göteborg, Sweden.
Int J Prosthodont. 2003 Jul-Aug;16(4):415-21.
This study evaluated and compared the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with that of conventional cast frameworks in the partially edentulous jaw.
Forty-two patients provided with Brånemark system implants were arranged into two groups. Twenty-one patients (group A) were provided with a conventional cast ceramometal framework in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain in the other side. In group B, 21 patients received a titanium framework prosthesis to replace a conventional implant prosthesis. Clinical and radiographic data were collected for 5 years.
Four implants and one titanium framework were lost during the follow-up period. The two framework designs did not show any significant differences with regard to implant or prosthesis survival (P > .05). Few clinical complications were observed. In group A, marginal bone loss after 5 years was similar for both prosthesis designs, with an average of 0.1 mm and 0.3 mm in the maxilla and mandible, respectively. Basically, no bone loss was observed on average in group B. Furthermore, no significant relationship was observed between marginal bone loss and placement of prosthesis margin or prosthesis design.
Except for an insignificant tendency toward a slightly higher incidence of small chips of porcelain veneers, laser-welded titanium frameworks presented an overall similar clinical performance as conventional cast frameworks in partial implant situations after 5 years.
本研究评估并比较了激光焊接钛制种植体支持的固定局部义齿与传统铸造支架在部分牙列缺损颌骨中的临床性能。
42例植入Brånemark系统种植体的患者被分为两组。21例患者(A组)一侧颌骨采用传统铸造金属烤瓷支架,另一侧采用激光焊接钛支架和低熔瓷。B组21例患者接受钛支架义齿以替代传统种植义齿。收集临床和影像学数据,为期5年。
随访期间有4枚种植体和1个钛支架丢失。两种支架设计在种植体或义齿存留率方面未显示出任何显著差异(P>0.05)。观察到的临床并发症较少。A组中,5年后两种义齿设计的边缘骨吸收情况相似,在上颌和下颌平均分别为0.1mm和0.3mm。B组平均基本未观察到骨吸收。此外,边缘骨吸收与义齿边缘位置或义齿设计之间未观察到显著关系。
除了烤瓷贴面小碎片发生率略高这一不显著的倾向外,5年后在部分种植情况下,激光焊接钛支架与传统铸造支架的总体临床性能相似。