视觉模拟评分法测量急性疼痛的可靠性。

Reliability of the visual analog scale for measurement of acute pain.

作者信息

Bijur P E, Silver W, Gallagher E J

机构信息

Department of Emergency Medicine, Albert Einstein College of Medicine, Bronx, NY 10461, USA.

出版信息

Acad Emerg Med. 2001 Dec;8(12):1153-7. doi: 10.1111/j.1553-2712.2001.tb01132.x.

Abstract

OBJECTIVE

Reliable and valid measures of pain are needed to advance research initiatives on appropriate and effective use of analgesia in the emergency department (ED). The reliability of visual analog scale (VAS) scores has not been demonstrated in the acute setting where pain fluctuation might be greater than for chronic pain. The objective of the study was to assess the reliability of the VAS for measurement of acute pain.

METHODS

This was a prospective convenience sample of adults with acute pain presenting to two EDs. Intraclass correlation coefficients (ICCs) with 95% confidence intervals (95% CIs) and a Bland-Altman analysis were used to assess reliability of paired VAS measurements obtained 1 minute apart every 30 minutes over two hours.

RESULTS

The summary ICC for all paired VAS scores was 0.97 [95% CI = 0.96 to 0.98]. The Bland-Altman analysis showed that 50% of the paired measurements were within 2 mm of one another, 90% were within 9 mm, and 95% were within 16 mm. The paired measurements were more reproducible at the extremes of pain intensity than at moderate levels of pain.

CONCLUSIONS

Reliability of the VAS for acute pain measurement as assessed by the ICC appears to be high. Ninety percent of the pain ratings were reproducible within 9 mm. These data suggest that the VAS is sufficiently reliable to be used to assess acute pain.

摘要

目的

需要可靠且有效的疼痛测量方法,以推进关于急诊科(ED)合理有效使用镇痛药物的研究项目。视觉模拟量表(VAS)评分的可靠性在急性疼痛环境中尚未得到证实,因为急性疼痛的波动可能比慢性疼痛更大。本研究的目的是评估VAS测量急性疼痛的可靠性。

方法

这是一项对两家急诊科就诊的急性疼痛成人患者的前瞻性便利样本研究。使用组内相关系数(ICC)及95%置信区间(95%CI)和Bland-Altman分析来评估在两小时内每30分钟间隔1分钟获得的配对VAS测量值的可靠性。

结果

所有配对VAS评分的汇总ICC为0.97[95%CI = 0.96至0.98]。Bland-Altman分析表明,50%的配对测量值彼此相差在2毫米以内,90%相差在9毫米以内,95%相差在16毫米以内。配对测量值在疼痛强度的极端情况下比在中等疼痛水平时更具可重复性。

结论

通过ICC评估,VAS测量急性疼痛的可靠性似乎很高。90%的疼痛评分在9毫米内可重复。这些数据表明,VAS足够可靠,可用于评估急性疼痛。