Suppr超能文献

气相色谱/质谱联用同时测定尿液中的苯乙烯、甲苯和二甲苯代谢物

Simultaneous determination of styrene, toluene, and xylene metabolites in urine by gas chromatography/mass spectrometry.

作者信息

Szucs Sándor, Tóth László, Legoza József, Sárváry Attila, Adány Róza

机构信息

Debreceni Egyetem, Orvos- és Egészségtudományi Centrum, Népegészségügyi Iskola, Megelozo Orvostani Intézet, 4012 Debrecen, Pf. 9, Hungary.

出版信息

Arch Toxicol. 2002 Oct;76(10):560-9. doi: 10.1007/s00204-002-0384-0. Epub 2002 Aug 27.

Abstract

Exposure to styrene, toluene, and xylene (STX) frequently occurs in various industrial settings leading to several adverse health effects. Therefore, the biological monitoring by determination of urinary mandelic acid (MA) and phenylglyoxylic acid (PGA), hippuric acid (HA), and 2-, 3-, and 4-methylhippuric acids (2-, 3-, and 4-MHAs), the metabolites of STX, is required or at least recommended in case of workers exposed by these agents. Considering the fact that co-exposure to STX frequently occurs, methods that have been described for the separate analysis of these compounds in urine samples cannot be used effectively for monitoring. Therefore, a reliable gas chromatographic/mass spectrometric (GC/MS) method was developed for the simultaneous identification and quantification of these metabolites. Following solid phase extraction of the urine samples, the extracts were silylated and analyzed by GC/MS using a HP-5MS capillary column. The method was evaluated for linearity, limits of detection and quantification, and specificity, as well as for precision, extraction efficiency, and stability at three different concentrations prepared in urine. The assay was linear up to 0.16 mg/ml for MA, and 0.32 mg/ml for PGA, HA, and 2-, 3- and 4-MHAs. The limits of detection and quantification of STX metabolites varied between 0.001 and 0.02 mg/ml, and from 0.01 to 0.04 mg/ml, respectively. The within-day and between-day precision, determined at low, medium, and high concentrations, ranged from 2 to 12% and 2 to 19%, respectively. The extraction efficiency was 70-80%. No degradation of the metabolites occurred in the urine samples under the possible working conditions. The method was applied for the analysis of the urine samples from exposed workers. The cost- and time-effectiveness, the technical advantages and validity parameters of this GC/MS analysis make it suitable for biological monitoring of mixed exposure to styrene, toluene and xylene.

摘要

在各种工业环境中,人们经常会接触到苯乙烯、甲苯和二甲苯(STX),这会导致多种不良健康影响。因此,对于接触这些物质的工人,需要或至少建议通过测定尿中扁桃酸(MA)、苯乙酮酸(PGA)、马尿酸(HA)以及2-、3-和4-甲基马尿酸(2-、3-和4-MHA)(STX的代谢产物)来进行生物监测。鉴于经常会发生对STX的共同接触,已报道的用于单独分析尿样中这些化合物的方法无法有效地用于监测。因此,开发了一种可靠的气相色谱/质谱(GC/MS)方法,用于同时鉴定和定量这些代谢产物。尿样经固相萃取后,提取物进行硅烷化处理,并使用HP-5MS毛细管柱通过GC/MS进行分析。该方法针对线性、检测限和定量限、特异性以及在尿中制备的三种不同浓度下的精密度、提取效率和稳定性进行了评估。该测定法对于MA的线性范围高达0.16 mg/ml,对于PGA、HA以及2-、3-和4-MHA的线性范围高达0.32 mg/ml。STX代谢产物的检测限和定量限分别在0.001至0.02 mg/ml和0.01至0.04 mg/ml之间。在低、中、高浓度下测定的日内和日间精密度分别为2%至12%和2%至19%。提取效率为70 - 80%。在可能的工作条件下,尿样中的代谢产物未发生降解。该方法应用于分析接触工人的尿样。这种GC/MS分析的成本效益和时间效益、技术优势以及有效性参数使其适用于对苯乙烯、甲苯和二甲苯混合接触的生物监测。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验