Monoclonal antibodies against human fibroblast collagenase and the design of an enzyme-linked immunosorbent assay to measure total collagenase.

作者信息

Clark I M, Powell L K, Wright J K, Cawston T E, Hazleman B L

机构信息

Rheumatology Research Unit, Addenbrooke's Hospital, Cambridge, UK.

出版信息

Matrix. 1992 Dec;12(6):475-80. doi: 10.1016/s0934-8832(11)80092-2.

Abstract

Monoclonal antibodies have been raised against purified human fibroblast collagenase and characterised. One of these antibodies has been used in combination with a polyclonal anticollagenase antibody in a double antibody sandwich ELISA to measure collagenase. The assay range was 2-50 ng/ml collagenase. The assay measures total collagenase, i.e. pro- and active enzyme as well as collagenase in complex with TIMP. The level of collagenase has been measured in sera samples from patients with rheumatoid arthritis and compared with age- and sex-matched controls. The levels measured were: rheumatoid arthritis, 69 +/- 29 ng/ml; normal, 49 +/- 14 ng/ml.