The relative biological effectiveness of 60Co gamma-rays, 55 kVp X-rays, 250 kVp X-rays, and 11 MeV electrons at low doses.

作者信息

Spadinger I, Palcic B

机构信息

Cancer Imaging, BC Cancer Research Centre, Vancouver, Canada.

出版信息

Int J Radiat Biol. 1992 Mar;61(3):345-53. doi: 10.1080/09553009214551031.

Abstract

The relative biological effectiveness (RBE) of selected low-LET radiation modalities (55 kVp X-rays, 250 kVp X-rays, 60Co gamma-rays, and 11 MeV electrons) was investigated for survival of two cell lines (V79 and CHO). Detailed measurements were made in the low (0 to 3 Gy) dose range using an image cytometry device to accurately determine the number of cells assayed at each dose point. Data were also collected in the high dose range (0 to 10 Gy) using conventional counting and plating techniques. RBE values (+/- 1 SE) varied from 1.0 +/- 0.07 (V79 cells) and 1.2 +/- 0.05 (CHO cells) at high doses to 1.3 +/- 0.07 (V79) and 1.4 +/- 0.1 (CHO) at low doses for 55 kVp X-rays, from 1.1 +/- 0.05 (V79) and 1.1 +/- 0.04 (CHO) at high doses to 1.1 +/- 0.06 (V79) and 1.2 +/- 0.2 (CHO) at low doses for 250 kVp X-rays, and from 1.1 +/- 0.08 (V79) and 1.0 +/- 0.04 (CHO) at high doses to 1.0 +/- 0.06 (V79) and 0.9 +/- 0.1 (CHO) at low doses for 11 MeV electrons. Only the low and high dose RBEs for 55 kVp X-rays relative to 60Co gamma-rays were significantly different.

摘要

研究了选定的低传能线密度(LET)辐射模式(55 kVp X射线、250 kVp X射线、60Coγ射线和11 MeV电子)对两种细胞系(V79和CHO)存活的相对生物效能(RBE)。在低剂量范围(0至3 Gy)使用图像细胞仪进行详细测量,以准确确定每个剂量点检测的细胞数量。在高剂量范围(0至10 Gy)也使用传统计数和平板技术收集数据。对于55 kVp X射线,RBE值(±1标准误差)从高剂量时的1.0±0.07(V79细胞)和1.2±0.05(CHO细胞)变化到低剂量时的1.3±0.07(V79)和1.4±0.1(CHO);对于250 kVp X射线,从高剂量时的1.1±0.05(V79)和1.1±0.04(CHO)变化到低剂量时的1.1±0.06(V79)和1.2±0.2(CHO);对于11 MeV电子,从高剂量时的1.1±0.08(V79)和1.0±0.04(CHO)变化到低剂量时的1.0±0.06(V79)和0.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验