Suppr超能文献

使用视盘数据对青光眼可疑患者视神经乳头测量的观察者内和观察者间变异

Intra- and inter-observer variation of optic nerve head measurements in glaucoma suspects using disc-data.

作者信息

Stürmer J, Poinoosawmy D, Broadway D C, Hitchings R A

机构信息

Moorfields Eye Hospital, Glaucoma Unit, London, UK.

出版信息

Int Ophthalmol. 1992 Sep;16(4-5):227-33. doi: 10.1007/BF00917966.

Abstract

The aim of this study was to determine the intra- and inter-observer variation in the use of a system designed for exact measurements from standard optic nerve head photographs. The commercially available system consisted of a colour CCD Videocamera, a dedicated frame grabber and customized software run on a IBM AT compatible computer. Masked measurements were made 3 times by 2 observers, from stereophotographs of the optic nerve head of 56 eyes from 30 glaucoma suspects. The cup was defined on the basis of contour, not pallor and the disc area was defined as the area inside Elschnig's ring. Intra-observer variances were 0.001 +/- 0.001 mm2 for cup area (mean +/- SD), 0.002 +/- 0.002 mm2 for disc area and 0.002 +/- 0.003 mm2 for rim area. These values for intra-observer variance were comparable with the results obtained using manual planimetric techniques. Intra-observer variance for disc area was significantly larger for the less trained of the two experienced observers. Inter-observer variances were 0.004 +/- 0.009 mm2 for cup area, 0.008 +/- 0.013 mm2 for disc area and 0.009 +/- 0.014 mm2 for rim area. These inter-observer variances were significantly larger than those previously reported for manual planimetry. The absolute differences between the two observers ranged from -0.35 to +0.20 mm2 (-0.08 +/- 0.11 mm2) for cup area, from -0.38 to +0.15 mm2 (-0.08 +/- 0.11 mm2) for disc area and from -0.29 to +0.34 mm2 (-0.06 +/- 0.12 mm2) for rim area.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究的目的是确定使用一种为从标准视神经乳头照片进行精确测量而设计的系统时,观察者内和观察者间的差异。该商用系统由一台彩色CCD摄像机、一个专用图像采集卡以及在IBM AT兼容计算机上运行的定制软件组成。两名观察者对30名青光眼疑似患者的56只眼睛的视神经乳头立体照片进行了3次盲法测量。视杯根据轮廓而非色泽来定义,视盘面积定义为Elschnig环内的面积。观察者内杯面积的方差为0.001±0.001mm²(均值±标准差),视盘面积为0.002±0.002mm²,视盘边缘面积为0.002±0.003mm²。这些观察者内方差值与使用手动平面测量技术获得的结果相当。在两名经验丰富的观察者中,训练较少的观察者视盘面积的观察者内方差显著更大。观察者间杯面积的方差为0.004±0.009mm²,视盘面积为0.008±0.013mm²,视盘边缘面积为0.009±0.014mm²。这些观察者间方差显著大于先前报道的手动平面测量法的方差。两名观察者之间杯面积的绝对差值在-0.35至+0.20mm²(-0.08±0.11mm²)之间,视盘面积在-0.38至+0.15mm²(-0.08±0.11mm²)之间,视盘边缘面积在-0.29至+0.34mm²(-0.06±0.12mm²)之间。(摘要截选至250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验