通过光学相干断层扫描对角膜肿胀期间角膜光背散射进行客观测量。

Objective measurements of corneal light-backscatter during corneal swelling, by optical coherence tomography.

作者信息

Wang Jianhua, Simpson Trefford L, Fonn Desmond

机构信息

Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.

出版信息

Invest Ophthalmol Vis Sci. 2004 Oct;45(10):3493-8. doi: 10.1167/iovs.04-0096.

Abstract

PURPOSE

To demonstrate that corneal light-backscatter can be measured objectively during corneal swelling by optical coherence tomography (OCT).

METHODS

One eye (randomly selected) of 20 non-contact-lens wearers (10 men and 10 women; mean age, 35.6 +/- 9.6 years) was patched during 3 hours of soft contact lens (SCL) wear. The contralateral eye acted as the control. Central corneal images were captured before and after SCL wear at 20-minute intervals over 100 minutes using optical coherence tomography (OCT) to obtain corneal thickness and light-backscatter profiles. OCT backscattered light of the epithelial layer (decided by the thickness measurements) and 10 equally divided layers of the remaining cornea were analyzed with a custom software program. Two baseline measurements were taken at different visits before lens wear to test the repeatability of light-backscatter measurements.

RESULTS

From two baseline measurements, repeated measurements showed good repeatability of normalized backscatter results. Immediately after contact lens removal, total central corneal thickness increased significantly by 13.8% +/- 2.3% (mean +/- SD) compared with baseline (P = 0.0001, paired t-test) and then decreased during the deswelling course. Corneal backscattered light changed significantly (repeated-measures ANOVA [Re-ANOVA]: F((50, 950)) = 2.22, P = 0.0001) after lens wear, and a significant increase in backscatter was found in the epithelial layer (36.4%) and the most posterior corneal layer (35.6%) immediately after lens removal (post hoc test, P = 0.005). There was a strong correlation (r = 0.9375, P < 0.05) between the change in backscatter and corneal swelling during the deswelling period. The backscatter recovery rate was approximately the same for both epithelial and posterior layers after lens removal.

CONCLUSIONS

Light-backscattering analysis with OCT seems to be a promising and repeatable method of objectively measuring corneal backscatter. This study has demonstrated that corneal backscattered light increased in the anterior and posterior layers of the cornea during corneal swelling induced by contact lens wear and eye closure.

摘要

目的

通过光学相干断层扫描(OCT)证明在角膜肿胀期间可客观测量角膜光背散射。

方法

20名不佩戴隐形眼镜者(10名男性和10名女性;平均年龄35.6±9.6岁)中的一只眼睛(随机选择)在佩戴软性隐形眼镜(SCL)3小时期间被遮盖。对侧眼作为对照。在100分钟内每隔20分钟使用光学相干断层扫描(OCT)在佩戴SCL前后采集中央角膜图像,以获得角膜厚度和光背散射轮廓。使用定制软件程序分析上皮层(由厚度测量确定)和剩余角膜的10个等分层的OCT背散射光。在佩戴镜片前的不同访视中进行两次基线测量,以测试光背散射测量的可重复性。

结果

从两次基线测量来看,重复测量显示归一化背散射结果具有良好的可重复性。摘除隐形眼镜后即刻,中央角膜总厚度较基线显著增加13.8%±2.3%(平均值±标准差)(P = 0.0001,配对t检验),然后在消肿过程中下降。佩戴镜片后角膜背散射光发生显著变化(重复测量方差分析[Re-ANOVA]:F((50, 950)) = 2.22,P = 0.0001),摘除镜片后即刻上皮层(36.4%)和角膜最后层(35.6%)的背散射显著增加(事后检验,P = 0.005)。在消肿期,背散射变化与角膜肿胀之间存在强相关性(r = 0.9375,P < 0.05)。摘除镜片后上皮层和后层的背散射恢复率大致相同。

结论

OCT光背散射分析似乎是一种有前景且可重复的客观测量角膜背散射的方法。本研究表明,在佩戴隐形眼镜和闭眼引起的角膜肿胀期间,角膜前层和后层的背散射光增加。