Playfor Stephen D
Honorary Clinical Lecturer in Paediatric Intensive Care Medicine, Paediatric Intensive Care Unit, Royal Manchester Children's Hospital, Manchester, UK.
Crit Care. 2005 Feb;9(1):25-6. doi: 10.1186/cc3001. Epub 2004 Nov 17.
The bispectral index (BIS) is a processed neurophysiological electroencephalographic parameter that may be used to evaluate the depth of sedation in critically ill children. Triltsch and colleagues attempted to correlate BIS scores with a commonly used clinical sedation scoring system. They were able to demonstrate good correlation during deep sedation and in cases where the electrical impedance of the BIS electrodes was lowest. Studies have shown only moderate degrees of correlation between BIS scores and clinical sedation scoring systems. There is currently insufficient evidence to recommend routine monitoring of BIS scores in critically ill children.
脑电双频指数(BIS)是一种经过处理的神经生理脑电图参数,可用于评估危重症患儿的镇静深度。特里尔奇及其同事试图将BIS评分与一种常用的临床镇静评分系统进行关联。他们发现在深度镇静期间以及BIS电极电阻最低的情况下,二者具有良好的相关性。研究表明,BIS评分与临床镇静评分系统之间仅存在中等程度的相关性。目前尚无足够证据推荐对危重症患儿常规监测BIS评分。