Abstract

This study compared the use of different test models to assess the cytotoxicity of a dental composite. The cytotoxicity of a composite polymerized using two halogen-based light-curing units (LCUs) (Max LC and Astralis) and two light-emitting diode LCUs (E-light and Freelight) served as the basis of comparison. Disk-shaped specimens (7 mm diameter, 2 mm high) were fabricated using the four different light sources. The specimens were used in several cytotoxicity test models: direct and indirect contact tests as well as an extract test with an established cell line L-929. The cells were stained with neutral red after cell-material contact for 48 h. Neutral red-stained areas (in mm2, for direct and indirect tests) and absorbance readings (for extract tests) were analysed statistically using ANOVA and the Tukey post hoc test, with P < 0.05 considered to be significantly different. Good correlation between direct and indirect contact tests (r = 0.903) was found. The extract test was the least correlated among the three tests. It was found that the E-light + Freelight-cured composite elicited cytotoxicity from the correlated studies. Uncured specimens were most detrimental to the cells in all tests. Our data demonstrated that composite cured with light-emitting diode LCUs were cytotoxic to L-929 cells. Different test models were found to give rise to different findings. Thus, a good cell-material contact method would replicate more closely the physiological situation in vivo. This in turn would give more clinically relevant results.

摘要

本研究比较了使用不同测试模型评估牙科复合材料细胞毒性的情况。以使用两种卤素基光固化装置(LCU)(Max LC和Astralis)以及两种发光二极管LCU(E-light和Freelight)聚合的复合材料的细胞毒性作为比较基础。使用四种不同光源制作圆盘状标本(直径7毫米,高2毫米)。这些标本用于几种细胞毒性测试模型:直接和间接接触测试以及使用已建立的细胞系L-929进行的提取物测试。细胞与材料接触48小时后用中性红染色。使用方差分析(ANOVA)和Tukey事后检验对中性红染色面积(直接和间接测试中,单位为平方毫米)和吸光度读数(提取物测试中)进行统计学分析,P < 0.05被认为有显著差异。发现直接和间接接触测试之间具有良好的相关性(r = 0.903)。提取物测试在这三种测试中相关性最低。从相关研究中发现,E-light + Freelight固化的复合材料引发了细胞毒性。在所有测试中,未固化的标本对细胞的损害最大。我们的数据表明,用发光二极管LCU固化的复合材料对L-929细胞具有细胞毒性。发现不同的测试模型会产生不同的结果。因此,良好的细胞 - 材料接触方法将更紧密地模拟体内的生理情况。这反过来会产生更具临床相关性的结果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验