Suppr超能文献

不稳定注视对多焦视网膜电图(mfERG)的影响。

Effects of unsteady fixation on multifocal electroretinogram (mfERG).

作者信息

Chu Patrick H W, Chan Henry H L, Leat Susan J

机构信息

School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, SAR, People's Republic of China.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2006 Oct;244(10):1273-82. doi: 10.1007/s00417-006-0304-8. Epub 2006 Mar 21.

Abstract

PURPOSE

To investigate the effect of unsteady fixation on the multifocal electroretinogram (mfERG) measurement in normal subjects.

METHODS

The mfERGs of 20 subjects with normal vision (mean age=23.5 years) were recorded with different levels of voluntary eye movements made to mimic unsteady fixation. Subjects were required to move their fixation regularly every 2 s between the center and the ends of a fixation cross, so that 51.2% of the time fixation was at the center and 12.2% of the time it was at each end of the fixation cross. Four different conditions were performed: central fixation (without voluntary eye movements) and with 2 degrees, 4 degrees and 6 degrees magnitude of unsteady fixation. First-order kernel mfERG findings are presented.

RESULTS

Analysis of the ring responses indicated that the central mfERG amplitude was most affected by unsteady fixation. There was significantly reduced amplitude for 4 degrees unsteady fixation and as expected, this reduction became larger with 6 degrees unstable fixation. However, there was no significant effect on the center hexagon amplitude for 2 degrees unsteady fixation. The amplitudes of the ring-2 responses were only affected in the 6 degrees unsteady fixation condition. No significant change in implicit time was found for any level of unsteady fixation.

CONCLUSION

These results suggest that mfERG amplitude is not substantially affected if fixation is maintained within the central stimulus hexagon. We conclude that, for patients with poor fixation, the accuracy of mfERG results may be difficult to interpret and the use of a fixation-monitoring system is desirable for ideal measurement. The depth of depression at the blind spot area may be another useful parameter to interpret the accuracy of mfERG results in patients with poor fixation.

摘要

目的

研究不稳定注视对正常受试者多焦视网膜电图(mfERG)测量的影响。

方法

对20名视力正常的受试者(平均年龄 = 23.5岁)进行mfERG记录,通过模拟不稳定注视,让受试者进行不同程度的自主眼球运动。要求受试者每2秒在注视十字的中心和两端之间有规律地移动注视点,使得51.2%的时间注视点位于中心,12.2%的时间位于注视十字的每个端点。共进行了四种不同情况:中心注视(无自主眼球运动)以及不稳定注视幅度为2度、4度和6度。呈现了一阶核mfERG的结果。

结果

对环形反应的分析表明,中心mfERG振幅受不稳定注视影响最大。4度不稳定注视时振幅显著降低,正如预期,6度不稳定注视时这种降低更为明显。然而,2度不稳定注视时对中心六边形振幅没有显著影响。环形2反应的振幅仅在6度不稳定注视情况下受到影响。对于任何程度的不稳定注视,未发现潜伏期有显著变化。

结论

这些结果表明,如果注视保持在中心刺激六边形内,mfERG振幅不会受到实质性影响。我们得出结论,对于注视不佳的患者,mfERG结果的准确性可能难以解释,理想的测量需要使用注视监测系统。盲点区域凹陷的深度可能是另一个有用的参数,用于解释注视不佳患者mfERG结果的准确性。