Suppr超能文献

[具有阳极氧化表面的牙内种植体的系统定性组织学研究]

[Systematic qualitative histology of enossal implants with anodically oxidised surfaces].

作者信息

Al-Nawas B, Grötz K A, Goetz H, Feil M, Duschner H, Wagner W

机构信息

Mund-Kiefer-Gesichtschirurgie, Uniklinik Mainz, Augustusplatz 2, 55131, Mainz, Germany.

出版信息

Mund Kiefer Gesichtschir. 2006 Jul;10(4):229-37. doi: 10.1007/s10006-006-0002-z.

Abstract

Histological analysis of dental implants is often quantified by calculating the bone-implant contact rate (bone volume/total volume), whereas qualitative aspects like osteoconduction are underrepresented. The aim of this study was to focus on the micro-architectural properties of the bone-implant contact under physiologic loading using a systematic analysis of these characteristics. In 16 Beagle dogs we inserted 6 different types of dental implants in the hard bone of the mandible and the soft bone of the maxilla. After a healing period of two months the implants were loaded for three months and then histologically analysed. For the metric evaluation of qualitative histological aspects 12 examiners answered pivotal questions: 1. Is the implant functional sufficient? 2. Do you see close contact to bone, were bone is present? 3. Is the amount of bone at the implant at least similar to the peripheral bone? 4. Is the bone to implant contact homogenous? 5. Does the bone show a functional architecture? 6. Do you find osseoconductive bone apposition at the crestal and apical border? A superiority of anodic oxidized surfaces can be seen in questions 1, 2 and 3 mainly for the comparison of identical macrodesigns (MkIII). The potential for osseoconductivity (questions 4 and 5) shows a tendency for significant differences for the ZL Ticer implant. Homogenous bone to implant contact is rarely found, in contrast to rather positive implant function ratings. This suggests the existence of an optimum in the bone to implant contact rate. Bone to implant contact rate as an isolated quantitative parameter should in future be completed by a systematic, standardised and blinded analysis of qualitative properties.

摘要

牙种植体的组织学分析通常通过计算骨-种植体接触率(骨体积/总体积)来量化,而诸如骨传导性等定性方面的研究较少。本研究的目的是通过对这些特征进行系统分析,聚焦于生理负荷下骨-种植体接触的微观结构特性。在16只比格犬的下颌硬骨和上颌软骨中植入6种不同类型的牙种植体。经过两个月的愈合期后,对种植体进行三个月的加载,然后进行组织学分析。为了对定性组织学方面进行量化评估,12名检查人员回答了关键问题:1. 种植体功能是否足够?2. 在有骨存在的地方,你是否看到与骨紧密接触?3. 种植体处的骨量是否至少与周边骨量相似?4. 骨与种植体的接触是否均匀?5. 骨是否呈现功能性结构?6. 在种植体的嵴顶和根尖边界处是否发现骨传导性骨附着?主要在对相同宏观设计(MkIII)进行比较时,在问题1、2和3中可以看出阳极氧化表面具有优势。骨传导性潜力(问题4和5)显示ZL Ticer种植体存在显著差异的趋势。与相当积极的种植体功能评级相反,很少发现骨与种植体的均匀接触。这表明骨-种植体接触率存在一个最佳值。作为一个单独的定量参数,骨-种植体接触率未来应通过对定性特性进行系统、标准化和盲法分析来完善。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验