We present a new approach for biomass assessment in cell culture using a disposable microcentrifuge tube. The specially designed tube is fitted with an upper chamber for sample loading and a lower 5 microL capillary for cell collection during centrifugation. The resulting packed cell volume (PCV) can be quantitatively expressed as the percentage of the total volume of the sample. The present study focused on the validation of the method with mammalian cell lines that are widely used in bioprocessing. Using several examples, the PCV method was shown to be more precise, rapid, and reproducible than manual cell counting.
我们提出了一种使用一次性微量离心管进行细胞培养中生物量评估的新方法。这种经过特殊设计的管子配有一个用于装载样品的上腔室和一个用于在离心过程中收集细胞的5微升下毛细管。所得的血细胞压积(PCV)可以定量表示为样品总体积的百分比。本研究重点是用生物加工中广泛使用的哺乳动物细胞系对该方法进行验证。通过几个例子表明,与手动细胞计数相比,PCV方法更精确、快速且可重复。