Suppr超能文献

巴伐利亚高山气候地区三家提供过敏性疾病住院康复治疗的医院中的室内过敏原和内毒素——AURA研究

Domestic allergens and endotoxin in three hospitals offering in-patient rehabilitation for allergic diseases in the alpine mountain climate of Bavaria - The AURA study.

作者信息

Eberlein B, Gulyas A F, Schultz K, Lecheler J, Flögel S, Wolfmeyer C, Thiessen K, Jakob T, Schuster T, Hollweck R, Ring J, Behrendt H

机构信息

Division of Environmental Dermatology and Allergology, GSF/TUM, Neuherberg, Munich, Germany.

出版信息

Int J Hyg Environ Health. 2009 Jan;212(1):21-6. doi: 10.1016/j.ijheh.2007.09.003. Epub 2007 Dec 26.

Abstract

Endotoxins and allergens represent the major relevant contents of the atmospheric bioaerosol with regard to the triggering and exacerbation of allergic diseases. In this study, mattress concentrations of endotoxin and indoor allergens were measured in three hospitals in the alpine climate of Bavaria and in adjacent homes. Dust was collected from each of 10 mattresses according to a standardized protocol, and endotoxin was analyzed with the Limulus Amebocyte Lysate (LAL) test, indoor allergens Der p 1, Der f 1 and Fel d 1 were analyzed by ELISAs. The concentration of endotoxin in the mattresses did not differ significantly between different cities. The percentiles of endotoxin were significantly higher in hospitals than in homes. The concentrations of mite allergens (Der p 1 and Der f 1) in the dust were significantly lower in all hospitals than in homes. There was no significant difference of mite allergens between different time points. The concentrations of Fel d 1 were significantly higher in the autumn than in the summer (median: 1376 vs. 478ng/g). No significant differences of Fel d 1 were found between hospitals and homes or between different hospitals. As Fel d 1 concentrations reached levels at which cat allergic patients can experience symptoms, efforts had to be made to reduce the concentrations of Fel d 1 especially in hospitals. In contrast, mite allergens were low in hospitals, which can be clinically beneficial for patients with mite allergies.

摘要

就过敏性疾病的引发和加剧而言,内毒素和过敏原是大气生物气溶胶的主要相关成分。在本研究中,对巴伐利亚州高山气候地区的三家医院及其相邻住宅内床垫中的内毒素和室内过敏原浓度进行了测量。按照标准化方案从10个床垫中分别采集灰尘,采用鲎试剂法(LAL)检测内毒素,采用酶联免疫吸附测定法(ELISA)分析室内过敏原Der p 1、Der f 1和Fel d 1。不同城市床垫中的内毒素浓度无显著差异。医院内内毒素的百分位数显著高于住宅。所有医院灰尘中螨虫过敏原(Der p 1和Der f 1)的浓度均显著低于住宅。不同时间点的螨虫过敏原无显著差异。秋季Fel d 1的浓度显著高于夏季(中位数:1376 vs. 478ng/g)。医院与住宅之间或不同医院之间的Fel d 1无显著差异。由于Fel d 1浓度达到了猫过敏患者可能出现症状的水平,因此必须努力降低Fel d 1的浓度,尤其是在医院。相比之下,医院内螨虫过敏原含量较低,这对螨虫过敏患者在临床上可能有益。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验