Suppr超能文献

使用微切口无像差非球面人工晶状体的临床结果及术后眼内光学质量

Clinical outcomes and postoperative intraocular optical quality with a microincision aberration-free aspheric intraocular lens.

作者信息

Alió Jorge L, Piñero David P, Ortiz Dolores, Montalbán Raúl

机构信息

Vissum Corporation-Instituto de Oftalmológico de Alicante, Miguel Hernandez University, Alicante, Spain.

出版信息

J Cataract Refract Surg. 2009 Sep;35(9):1548-54. doi: 10.1016/j.jcrs.2009.03.055.

Abstract

PURPOSE

To evaluate the visual outcomes and optical quality with an aspheric intraocular lens (IOL) with no aberration in microincision cataract surgery.

SETTING

Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain.

METHODS

This prospective cohort study included eyes that had cataract surgery with implantation of an Akreos Adapt Advanced Optics MI60 IOL. Surgery was performed using the Millennium phacoemulsification platform. The IOL was implanted through a sub-1.8 mm incision using the 1.8 Viscoglide cartridge. Visual and refractive outcomes were analyzed during a 12-month follow-up. In addition, postoperative ocular optical quality was evaluated using the Optical Quality Analysis System. Postoperative intraocular optical aberrations were calculated by subtracting corneal aberrations from total aberrations.

RESULTS

The cohort comprised 25 eyes of 25 patients ranging in age from 52 to 83 years. The mean spherical equivalent was -0.47 diopters +/- 0.62 (SD) 3 months postoperatively (P = .72). The mean corrected distance visual acuity improved from 0.54 +/- 0.23 logMAR preoperatively to 0.08 +/- 0.16 logMAR 3 months postoperatively (P<.01). Optical quality analysis showed a mean spatial frequency at 50% of the modulation transfer function (MTF) of 2.85 +/- 0.55 cycles per degree (cpd) and a mean cutoff MTF frequency of 21.50 +/- 7.02 cpd. Postoperatively, the mean intraocular spherical aberration was 0.16 +/- 0.11 microm and the mean primary coma root mean square, 0.23 +/- 0.15 microm.

CONCLUSION

Implantation of the aberration-free aspheric IOL was safe and effective and provided excellent visual and refractive outcomes with good optical performance.

摘要

目的

评估在微切口白内障手术中植入无像差非球面人工晶状体(IOL)后的视觉效果和光学质量。

地点

西班牙阿利坎特市的Vissum - 阿利坎特眼科研究所。

方法

这项前瞻性队列研究纳入了接受白内障手术并植入Akreos Adapt Advanced Optics MI60 IOL的眼睛。手术使用Millennium超声乳化平台进行。通过1.8 Viscoglide推注器经小于1.8 mm的切口植入IOL。在12个月的随访期间分析视觉和屈光结果。此外,使用光学质量分析系统评估术后眼的光学质量。通过从总像差中减去角膜像差来计算术后眼内光学像差。

结果

该队列包括25例患者的25只眼,年龄在52至83岁之间。术后3个月平均球镜等效度为-0.47屈光度±0.62(标准差)(P = 0.72)。平均矫正远视力从术前的0.54±0.23 logMAR提高到术后3个月的0.08±0.16 logMAR(P<0.01)。光学质量分析显示,调制传递函数(MTF)50%时的平均空间频率为2.85±0.55周/度(cpd),平均截止MTF频率为21.50±7.02 cpd。术后,平均眼内球差为0.16±0.11微米,平均初级彗差均方根为0.23±0.15微米。

结论

植入无像差非球面IOL安全有效,可提供出色的视觉和屈光效果以及良好的光学性能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验