Suppr超能文献

5种可折叠人工晶状体模型前囊收缩情况的比较

Comparison of anterior capsule contraction between 5 foldable intraocular lens models.

作者信息

Nagata Mayumi, Matsushima Hiroyuki, Mukai Koichiro, Terauchi Wataru, Gotoh Norihito, Matsui Eichiro

机构信息

Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu City, Tochigi, Japan.

出版信息

J Cataract Refract Surg. 2008 Sep;34(9):1495-8. doi: 10.1016/j.jcrs.2008.04.039.

Abstract

PURPOSE

To compare anterior capsule contraction in cataract patients having implantation of 1 of 5 foldable intraocular lens (IOL) models and evaluate lens epithelial cell (LEC) adhesion to each model.

SETTING

Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan.

METHODS

This study comprised 115 patients (126 eyes) without systemic or ocular complications who had phacoemulsification with IOL implantation. The eyes were randomly assigned to receive 1 of the following IOLs: acrylic MA60BM (Alcon), SA60AT (Alcon), AR40e (Advanced Medical Optics), or YA-60BBR (Hoya) or a silicone AQ310NV (Canon). Two weeks and 1, 3, and 6 months postoperatively, the anterior capsule opening area was measured using an anterior segment analysis system (EAS-1000, Nidek) and the percentage of anterior capsule contraction was compared for each postoperative period and IOL. Cell adhesion to each IOL type was evaluated using LECs from albino rabbits.

RESULTS

The mean age of the patients was 73.6 years +/- 5.6 (SD). Eyes with the AQ310NV and AR40e IOLs had statistically significantly greater anterior capsule contraction. The rabbit study showed statistically significantly less LEC adhesion on these 2 IOL models.

CONCLUSIONS

Anterior capsule contraction was significantly greater with the AQ310NV and AR40e IOLs than with the other IOLs. Results indicate that cell adhesion to the IOL is an important factor in preventing anterior capsule contraction.

摘要

目的

比较植入5种可折叠人工晶状体(IOL)模型之一的白内障患者的前囊收缩情况,并评估晶状体上皮细胞(LEC)与每种模型的黏附情况。

设置

日本栃木县独协医科大学眼科。

方法

本研究纳入115例(126只眼)无全身或眼部并发症且接受了白内障超声乳化吸除联合IOL植入术的患者。将这些眼随机分配接受以下IOL之一:丙烯酸酯MA60BM(爱尔康)、SA60AT(爱尔康)、AR40e(眼力健)、YA - 60BBR(豪雅)或硅酮AQ310NV(佳能)。术后2周、1个月、3个月和6个月,使用眼前节分析系统(EAS - 1000,尼德克)测量前囊开口面积,并比较每个术后时期及每种IOL的前囊收缩百分比。使用白化兔的LEC评估细胞与每种IOL类型的黏附情况。

结果

患者的平均年龄为73.6岁±5.6(标准差)。植入AQ310NV和AR40e IOL的眼的前囊收缩在统计学上显著更大。兔实验研究表明,这两种IOL模型上的LEC黏附在统计学上显著更少。

结论

AQ310NV和AR40e IOL的前囊收缩明显大于其他IOL。结果表明,细胞与IOL的黏附是预防前囊收缩的一个重要因素。