Marsack Jason D, Parker Katrina E, Applegate Raymond A
Visual Optics Institute, College of Optometry, University of Houston, Houston, Texas 77204, USA.
Optom Vis Sci. 2008 Dec;85(12):E1172-8. doi: 10.1097/OPX.0b013e31818e8eaa.
To examine whether custom wavefront-guided soft contact lenses provide visual and optical performance equivalent to habitual gas permeable (GP) corrections in three keratoconus subjects.
Custom wavefront-guided soft contact lenses were produced and evaluated at the Visual Optics Institute, College of Optometry, University of Houston for three habitual GP-wearing keratoconus subjects. Photopic high and mesopic low contrast logarithm of minimum angle of resolution visual acuity (logMAR VA) and residual second to tenth order optical aberrations experienced with these custom soft lenses were recorded and compared with the subjects' habitual GP correction.
All three subjects wearing custom soft lenses reached the established exit criterion of photopic high contrast (HC) logMAR VA equal to or better than values recorded with their habitual GP lens. HC logMAR VA for GP and custom soft lens correction was 0.01 +/- 0.05 and 0.00 +/- 0.02 for KC1, 0.20 +/- 0.02 and 0.14 +/- 0.02 for KC2, and 0.04 +/- 0.09 and -0.05 +/- 0.05 for KC3, respectively. In addition, KC2 reached the exit criterion of high-order aberration levels equal to or less than values with their habitual GP lens (GP lens: 0.394 +/- 0.024 microm, custom lens: 0.381 +/- 0.074 microm).
Custom wavefront-guided soft contact lenses have been demonstrated to provide equivalent photopic HC logMAR VA to that achieved with habitual GP correction in three keratoconus subjects. Future emphasis will be placed on surpassing habitual GP performance and reaching a normal age-matched criterion for both VA and aberration measures. Achieving these goals may require a more thorough understanding of the relationship between visual performance and residual aberration experienced during custom lens wear through the use of image quality metrics predictive of visual performance.
研究定制的波前引导软性接触镜在三名圆锥角膜患者中是否能提供与习惯性佩戴的透气性硬性(GP)角膜接触镜相当的视觉和光学性能。
在休斯顿大学视光学院视觉光学研究所为三名习惯性佩戴GP角膜接触镜的圆锥角膜患者制作并评估定制的波前引导软性接触镜。记录这些定制软性接触镜下的明视高对比度和中视低对比度最小分辨角视力(logMAR VA)以及残余的二阶至十阶光学像差,并与患者习惯性佩戴的GP角膜接触镜进行比较。
所有三名佩戴定制软性接触镜的患者均达到了既定的明视高对比度(HC)logMAR VA出口标准,即等于或优于其习惯性佩戴GP镜片时记录的值。对于KC1,GP和定制软性接触镜矫正的HC logMAR VA分别为0.01±0.05和0.00±0.02;对于KC2,分别为0.20±0.02和0.14±0.02;对于KC3,分别为0.04±0.09和 -0.05±0.05。此外,KC2达到了高阶像差水平等于或低于其习惯性佩戴GP镜片时的值的出口标准(GP镜片:0.394±0.024微米,定制镜片:0.381±0.074微米)。
已证明定制的波前引导软性接触镜在三名圆锥角膜患者中能提供与习惯性GP矫正相当的明视HC logMAR VA。未来的重点将是超越习惯性GP的性能,并在视力和像差测量方面达到与年龄匹配的正常标准。实现这些目标可能需要通过使用预测视觉性能的图像质量指标,更深入地了解定制镜片佩戴期间视觉性能与残余像差之间的关系。