Suppr超能文献

使用液相色谱-串联质谱法(LC-MS/MS)的被动采样装置在海水养殖中筛选微污染物的应用。

Application of passive sampling devices for screening of micro-pollutants in marine aquaculture using LC-MS/MS.

作者信息

Martínez Bueno María Jesús, Hernando María Dolores, Agüera Ana, Fernández-Alba Amadeo R

机构信息

Department of Hydrogeology and Analytical Chemistry, University of Almería, La Cañada de San Urbano, Almería, Spain.

出版信息

Talanta. 2009 Feb 15;77(4):1518-27. doi: 10.1016/j.talanta.2008.09.047. Epub 2008 Oct 9.

Abstract

Knowledge on the presence of micro-pollutants, in particular emerging contaminants, such as pharmaceuticals, biocides or some pesticides, in semi-enclosed coastal areas, where fish farms are installed, is very limited. This article shows data on the presence of micro-pollutants over 1 year monitoring campaign carried out in a fish farm placed on the Mediterranean Sea. With this work, the results of the development of an analytical procedure which, makes use of passive sampling techniques (with polar organic chemical integrative samplers, POCIS, pharmaceutical configuration) and of the LC-QLIT-MS system, are presented. The development of the analytical procedure entail laboratory-based calibration with the samplers POCIS, for calculating uptake rates and sampling rates of compounds representative of a wide range of polarity (4.56>or=logK(ow)>or=-0.12). The uptake of the target compounds in the sampler POCIS, follows a linear pattern for most compounds, and sampling rates varied from 0.001 to 0.319l/d. The calibration experiments have shown that POCIS pharmaceutical configuration could be used for sampling other non-target compounds, such as pesticides and biocides with a logK(ow)<or=4. The sampling rates for each selected compound were obtained using spiked seawater for further estimation of time-weighted average (TWA) concentration of micro-pollutants in the water column, during the field study. An analytical method was developed with the LC-QLIT-MS system and validated to ensure a satisfactory performance for the detection of the target micro-pollutants in water. The limits of detection (LODs) achieved were between 0.01 and 1.50 microg/l. During the monitoring campaign, among the selected compounds, metronidazole, erythromycin, simazine, atrazine, diuron, terbutryn, irgarol, trimethoprim, carbaryl, flumequine, TCMTB and diphenyl sulphone (DPS) were detected. Most of target compounds found were at average concentrations which ranged from 0.01 to 75 ng/l. Irgarol, simazine, diuron, atrazine and DPS were the micro-pollutants most frequently detected over the period of the monitoring programme carried out.

摘要

在设有养鱼场的半封闭沿海地区,关于微污染物,特别是新出现的污染物(如药品、杀生物剂或某些农药)存在情况的了解非常有限。本文展示了在位于地中海的一个养鱼场进行的为期1年监测活动中有关微污染物存在情况的数据。通过这项工作,介绍了一种分析程序的开发结果,该程序利用被动采样技术(使用极性有机化学综合采样器,即POCIS,药品配置)和LC-QLIT-MS系统。分析程序的开发需要使用POCIS采样器进行基于实验室的校准,以计算代表广泛极性范围(4.56≥logK(ow)≥-0.12)的化合物的摄取率和采样率。大多数化合物在POCIS采样器中的摄取呈线性模式,采样率从0.001到0.319升/天不等。校准实验表明,POCIS药品配置可用于采样其他非目标化合物,如logK(ow)≤4的农药和杀生物剂。在实地研究期间,使用加标海水获得了每种选定化合物的采样率,以进一步估计水柱中微污染物的时间加权平均(TWA)浓度。开发了一种使用LC-QLIT-MS系统的分析方法并进行了验证,以确保对水中目标微污染物的检测具有令人满意的性能。实现的检测限(LOD)在0.01至1.50微克/升之间。在监测活动期间,在所选定的化合物中,检测到了甲硝唑、红霉素、西玛津、莠去津、敌草隆、特丁净、藻菌清、甲氧苄啶、西维因、氟甲喹、2-噻吩甲酰三氟丙酮(TCMTB)和二苯砜(DPS)。发现的大多数目标化合物的平均浓度范围为0.01至75纳克/升。在进行的监测计划期间,藻菌清、西玛津、敌草隆莠去津和DPS是最常检测到的微污染物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验