Two simplified methods for quantitative lipoprotein analysis have been calibrated and compared with each other using analytic ultracentrifugation as a standard reference procedure. The first method was the Friedewald procedure and the second was an automated agarose gel electrophoresis system. Both procedures offer comparable quantitative lipoprotein analysis with potential for large scale screening purposes at low cost ($4.00-$5.00 per analysis). There were advantages and limitations to both procedures. The Friedwald procedure can be used on frozen sera but requires 3 ml sera. In contrast, the electrophoresis system must be used with fresh serum but requires only 50 mul serum and the electrophoretic slides may be quantitatively analyzed several years retrospectively.
两种用于定量脂蛋白分析的简化方法已通过使用分析超速离心作为标准参考程序进行校准并相互比较。第一种方法是弗里德瓦尔德法,第二种是自动琼脂糖凝胶电泳系统。这两种方法都能提供可比的定量脂蛋白分析,有潜力以低成本(每次分析4.00 - 5.00美元)用于大规模筛查目的。两种方法都有优点和局限性。弗里德瓦尔德法可用于冷冻血清,但需要3毫升血清。相比之下,电泳系统必须使用新鲜血清,但仅需要50微升血清,并且电泳载玻片可在数年后进行回顾性定量分析。