Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus.

作者信息

Dauwe Caroline, Touboul David, Roberts Cynthia J, Mahmoud Ashraf M, Kérautret Julien, Fournier Pierre, Malecaze François, Colin Joseph

机构信息

Department of Ophthalmology, Reference National Centers for Keratoconus, Bordeaux University, France.

出版信息

J Cataract Refract Surg. 2009 Oct;35(10):1761-7. doi: 10.1016/j.jcrs.2009.05.033.

Abstract

PURPOSE

To evaluate the biomechanical and morphological changes in keratoconic corneas after Intacs intrastromal corneal ring segment (ICRS) implantation.

SETTING

Department of Ophthalmology, National Reference Center for Keratoconus, Bordeaux University, Bordeaux, France.

METHODS

Keratoconic eyes were retrospectively analyzed after ICRS implantation; preoperative and 6-month postoperative evaluation were done using the Ocular Response Analyzer (ORA) and the Orbscan II topographer. Biomechanical parameters included corneal hysteresis (CH), the corneal resistance factor (CRF), and other parameters extracted from the signal curves. Morphological parameters included simulated keratometry and the cone location magnitude index from the axial map (aCLMI) and tangential map (tCLMI). Parameters were extracted using software designed to read and process topographic maps.

RESULTS

There were no significant differences between preoperatively and postoperatively in mean CH (7.7 mm Hg +/- 1.4 [SD] versus 7.4 +/- 1.4 mm Hg) or mean CRF (6.6 +/- 1.8 mm Hg versus 6.1 +/- 1.4 mm Hg). Only 2 ORA signal parameters were significantly different. Topographic parameters with significant decreases were minimum central keratometry (K) (mean change -5.8 +/- 2.9 diopters [D]) (P<.001), minimum central K (mean change -5.8 +/- 2.3 D) (P<.001), mean aCLMI (9.6 +/- 2.7 preoperatively versus 7.7 +/- 2.5 postoperatively) (P<.009), and mean tCLMI (18.9 +/- 2.8 versus 12.9 +/- 4.4) (P<.002). The only significant correlation between biomechanical and topographic parameters was postoperative ORA infrared signal peak 1 and postoperative aCLMI.

CONCLUSIONS

Intrastromal corneal ring implantation significantly decreased corneal curvature, with preoperative values predicting magnitude of change. However, it did not alter the viscoelastic biomechanical parameters of CH and CRF.

摘要

目的

评估角膜基质内角膜环片(ICRS)植入后圆锥角膜的生物力学和形态学变化。

设置

法国波尔多大学波尔多圆锥角膜国家参考中心眼科。

方法

对ICRS植入后的圆锥角膜眼进行回顾性分析;术前和术后6个月使用眼反应分析仪(ORA)和Orbscan II地形图仪进行评估。生物力学参数包括角膜滞后(CH)、角膜阻力因子(CRF)以及从信号曲线中提取的其他参数。形态学参数包括模拟角膜曲率计测量值以及轴向图(aCLMI)和切向图(tCLMI)中的圆锥位置大小指数。使用专门设计用于读取和处理地形图的软件提取参数。

结果

术前和术后平均CH(7.7 mmHg±1.4[标准差]对7.4±1.4 mmHg)或平均CRF(6.6±1.8 mmHg对6.1±1.4 mmHg)无显著差异。仅2个ORA信号参数有显著差异。显著降低的地形图参数包括最小中央角膜曲率(K)(平均变化-5.8±2.9屈光度[D])(P<0.001)、最小中央K(平均变化-5.8±2.3 D)(P<0.001)、平均aCLMI(术前9.6±2.7对术后7.7±2.5)(P<0.009)以及平均tCLMI(18.9±2.8对12.9±4.4)(P<0.002)。生物力学和地形图参数之间唯一显著相关的是术后ORA红外信号峰值1与术后aCLMI。

结论

角膜基质内环植入显著降低了角膜曲率,术前值可预测变化幅度。然而,它并未改变CH和CRF的粘弹性生物力学参数。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验