Department of Orthodontics, Faculty of Dentistry, University of Gaziantep, Gaziantep, Turkey.
Angle Orthod. 2010 Jan;80(1):195-200. doi: 10.2319/033007-155.1.
To test the null hypothesis that there are no statistically significant differences between flowables and an orthodontic adhesive tested in terms of shear bond strength (SBS) and pullout resistance.
To test the SBS of Light Bond, FlowTain, Filtek Supreme, and Tetric Flow were applied to the enamel surfaces of 15 teeth. Using matrices for application, each composite material was cured for 40 seconds and subjected to SBS testing. To test pullout resistance, 15 samples were prepared for each composite in which a wire was embedded; then the composite was cured for 40 seconds. Later, the ends of the wire were drawn up and tensile stress was applied until the resin failed. Findings were analyzed using an ANOVA and a Tukey HSD test.
The SBS values for Light Bond, FlowTain, Filtek Supreme, and Tetric Flow were 19.0 +/- 10.9, 14.7 +/- 9.3, 22.4 +/- 16.3, and 16.8 +/- 11.8 MPa, respectively, and mean pullout values were 42.2 +/- 13.0, 24.0 +/- 6.9, 26.3 +/- 9.4, and 33.8 +/- 18.0 N, respectively. No statistically significant differences were found among the groups in terms of SBS (P > .05). On the other hand, Light Bond yielded significantly higher pullout values compared with the flowables Filtek Supreme and Flow-Tain (P < .01). However, there were no significant differences among the pullout values of flowables, nor between Light Bond and Tetric Flow (P > .05).
The hypothesis is rejected. Light Bond yielded significantly higher pullout values compared with the flowables Filtek Supreme and FlowTain. However, flowable composites provided satisfactory SBS and wire pullout values, comparable to a standard orthodontic resin, and therefore can be used as an alternative for direct bonding of lingual retainers.
检验无统计学意义差异的零假设,即比较两种正畸粘接剂(光固化粘接剂和 FlowTain)和三种流动复合树脂(Filtek Supreme、Tetric Flow 和 FlowTain)的剪切粘接强度(SBS)和抗拔出力。
将 Light Bond、FlowTain、Filtek Supreme 和 Tetric Flow 应用于 15 颗牙齿的釉质表面,使用基质进行应用,每种复合材料固化 40 秒,然后进行 SBS 测试。为了测试抗拔出力,每种复合材料都准备了 15 个样本,其中嵌入了一根金属丝;然后将复合材料固化 40 秒。之后,拉动金属丝的末端并施加拉伸应力,直到树脂失效。使用方差分析和 Tukey HSD 检验对结果进行分析。
Light Bond、FlowTain、Filtek Supreme 和 Tetric Flow 的 SBS 值分别为 19.0 +/- 10.9、14.7 +/- 9.3、22.4 +/- 16.3 和 16.8 +/- 11.8 MPa,平均拔出值分别为 42.2 +/- 13.0、24.0 +/- 6.9、26.3 +/- 9.4 和 33.8 +/- 18.0 N。各组之间的 SBS 无统计学差异(P >.05)。另一方面,Light Bond 的拔出值明显高于流动复合树脂 Filtek Supreme 和 Flow-Tain(P <.01)。然而,流动复合树脂之间的拔出值没有显著差异,也没有 Light Bond 和 Tetric Flow 之间的差异(P >.05)。
该假设被拒绝。Light Bond 的拔出值明显高于流动复合树脂 Filtek Supreme 和 FlowTain。然而,流动复合树脂提供了令人满意的 SBS 和金属丝拔出值,与标准正畸树脂相当,因此可以作为直接粘结舌侧保持器的替代物。